OBJECTIVE: The study objective was to quantify the effects of different annuloplasty rings on mitral leaflet septal-lateral tenting areas during acute myocardial ischemia. METHODS: Radiopaque markers were implanted along the central septal-lateral meridian of the mitral valve in 30 sheep: 1 each to the septal and lateral aspects of the mitral annulus and 4 and 2 along the anterior and posterior mitral leaflets, respectively. Ten true-sized Carpentier-Edwards Physio, Edwards IMR ETLogix, and GeoForm annuloplasty rings (Edwards Lifesciences, Irvine, Calif) were inserted in a releasable fashion. Marker coordinates were obtained using biplane videofluoroscopy with ring inserted at baseline (RING_BL) and after 90 seconds of left circumflex artery occlusion (RING_ISCH). After ring release, another dataset was acquired before (No_Ring_BL) and after left circumflex artery occlusion (No_Ring_ISCH). Anterior and posterior mitral leaflet tenting areas were computed at mid-systole from sums of marker triangles with the midpoint between the annular markers being the vertex for all triangles. RESULTS: Compared with No_Ring_BL, mitral regurgitation grades and all tenting areas significantly increased with No_Ring_ISCH. Compared with No_Ring_ISCH, (1) all rings significantly prevented mitral regurgitation and reduced all tenting areas; (2) Edwards IMR ETLogix and GeoForm rings reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, to a significantly greater extent than the Carpentier-Edwards Physio ring; and (3) Edwards IMR ETLogix and GeoForm rings affected tenting areas similarly. CONCLUSIONS: In response to acute left ventricular ischemia, disease-specific functional/ischemic mitral regurgitation rings (Edwards IMR ETLogix, GeoForm) more effectively reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, compared with true-sized physiologic rings (Carpentier-Edwards Physio). Despite its radical 3-dimensional shape and greater amount of mitral annular septal-lateral downsizing, the GeoForm ring did not reduce tenting areas more than the Edwards IMR ETLogix ring, suggesting that further reduction in tenting areas in patients with FMR/IMR may not be effectively achieved on an annular level. Published by Mosby, Inc.
OBJECTIVE: The study objective was to quantify the effects of different annuloplasty rings on mitral leaflet septal-lateral tenting areas during acute myocardial ischemia. METHODS: Radiopaque markers were implanted along the central septal-lateral meridian of the mitral valve in 30 sheep: 1 each to the septal and lateral aspects of the mitral annulus and 4 and 2 along the anterior and posterior mitral leaflets, respectively. Ten true-sized Carpentier-Edwards Physio, Edwards IMR ETLogix, and GeoForm annuloplasty rings (Edwards Lifesciences, Irvine, Calif) were inserted in a releasable fashion. Marker coordinates were obtained using biplane videofluoroscopy with ring inserted at baseline (RING_BL) and after 90 seconds of left circumflex artery occlusion (RING_ISCH). After ring release, another dataset was acquired before (No_Ring_BL) and after left circumflex artery occlusion (No_Ring_ISCH). Anterior and posterior mitral leaflet tenting areas were computed at mid-systole from sums of marker triangles with the midpoint between the annular markers being the vertex for all triangles. RESULTS: Compared with No_Ring_BL, mitral regurgitation grades and all tenting areas significantly increased with No_Ring_ISCH. Compared with No_Ring_ISCH, (1) all rings significantly prevented mitral regurgitation and reduced all tenting areas; (2) Edwards IMR ETLogix and GeoForm rings reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, to a significantly greater extent than the Carpentier-Edwards Physio ring; and (3) Edwards IMR ETLogix and GeoForm rings affected tenting areas similarly. CONCLUSIONS: In response to acute left ventricular ischemia, disease-specific functional/ischemic mitral regurgitation rings (Edwards IMR ETLogix, GeoForm) more effectively reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, compared with true-sized physiologic rings (Carpentier-Edwards Physio). Despite its radical 3-dimensional shape and greater amount of mitral annular septal-lateral downsizing, the GeoForm ring did not reduce tenting areas more than the Edwards IMR ETLogix ring, suggesting that further reduction in tenting areas in patients with FMR/IMR may not be effectively achieved on an annular level. Published by Mosby, Inc.
Authors: David T Lai; Tomasz A Timek; Frederick A Tibayan; G Randall Green; George T Daughters; David Liang; Neil B Ingels; D Craig Miller Journal: Eur J Cardiothorac Surg Date: 2002-11 Impact factor: 4.191
Authors: Frederick A Tibayan; Filiberto Rodriguez; Mary K Zasio; Lynn Bailey; David Liang; George T Daughters; Frank Langer; Neil B Ingels; D Craig Miller Journal: Circulation Date: 2003-09-09 Impact factor: 29.690
Authors: Tomasz A Timek; Paul Dagum; David T Lai; David Liang; George T Daughters; Frederick Tibayan; Neil B Ingels; D Craig Miller Journal: J Thorac Cardiovasc Surg Date: 2003-02 Impact factor: 5.209
Authors: Wolfgang Bothe; Tomasz A Timek; Frederick A Tibayan; Mario Walther; George T Daughters; Neil B Ingels; D Craig Miller Journal: J Thorac Cardiovasc Surg Date: 2018-10-10 Impact factor: 5.209
Authors: Wolfgang Bothe; Ellen Kuhl; John-Peder Escobar Kvitting; Manuel K Rausch; Serdar Göktepe; Julia C Swanson; Saideh Farahmandnia; Neil B Ingels; D Craig Miller Journal: Circulation Date: 2011-09-13 Impact factor: 29.690
Authors: Wolfgang Bothe; Manuel K Rausch; John-Peder Escobar Kvitting; Dominique K Echtner; Mario Walther; Neil B Ingels; Ellen Kuhl; D Craig Miller Journal: Circulation Date: 2012-09-11 Impact factor: 29.690
Authors: Lik Chuan Lee; Martin Genet; Alan B Dang; Liang Ge; Julius M Guccione; Mark B Ratcliffe Journal: J Card Surg Date: 2014-04-07 Impact factor: 1.620
Authors: Tomasz A Timek; Marcin Malinowski; Robert L Hooker; Jessica L Parker; Charles L Willekes; Edward T Murphy; Theodore Boeve; Stephane Leung; Justin S Fanning; John C Heiser Journal: Ann Cardiothorac Surg Date: 2021-01