A carbon paste electrode was used for the electrochemical determination of linuron concentrations in water and vegetable extracts. Optimal conditions were established with respect to electrode activation (electrochemical pretreatment), time accumulation, potential accumulation, scan rate, and pH. The limit of detection achieved with a pre-concentration step was 23.0 μg L(-1). Recovery measurements in vegetable extract and natural water samples were in the range of 98-103%, indicating that the proposed electrochemical method can be employed to analyze linuron in these matrices. The determination results were in good agreement with HPLC results.
Copyright © 2010. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21238781     DOI: 10.1016/j.talanta.2010.12.014

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  p-Phenylenediamine-modified graphene oxide as a sorbent for solid-phase extraction of phenylurea herbicides, nitroimidazoles, chlorophenols, phenylurea insecticides and phthalates.

Authors:  Liying Guo; Lin Hao; Tian Gao; Chun Wang; Qiuhua Wu; Zhi Wang
Journal:  Mikrochim Acta       Date:  2019-06-22       Impact factor: 5.833

Review 2.  Recent Progress in Non-Enzymatic Electroanalytical Detection of Pesticides Based on the Use of Functional Nanomaterials as Electrode Modifiers.

Authors:  Tanja Vrabelj; Matjaž Finšgar
Journal:  Biosensors (Basel)       Date:  2022-04-20

3.  Voltammetric determination of the herbicide Linuron using a tricresyl phosphate-based carbon paste electrode.

Authors:  Jelena Ðorđević; Zsigmond Papp; Valéria Guzsvány; Ivan Svancara; Tatjana Trtić-Petrović; Milovan Purenović; Karel Vytřas
Journal:  Sensors (Basel)       Date:  2011-12-22       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.