Discordance between measured and calculated total carbon dioxide.

J P Ungerer1, M J Ungerer, W J Vermaak.   

Abstract

Recent studies on the agreement and correlation between measured and calculated total CO2 (TCO2) have yielded conflicting results. Pre-analytical variation could have been partially responsible. While keeping such variables at an absolute minimum, we found excellent correlation (r = 0.98) in 88 samples, with only a small variation in agreement between measured and calculated TCO2 values (SD = 1.1 mmol/L), which could be a function of variation in apparent pK (pK'). A subsequent evaluation of 913 consecutive samples, routinely analyzed, yielded similar results. These results suggest that some of the discrepancies reported in the literature could be ascribable to differences in sample types and sample handling. Rigid control of pre-analytical procedures is therefore a prerequisite in studies on this topic. The two methods were found to agree over a wide range of values, such that either of them could be used to evaluate clinical acid-base status accurately.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2123751

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  5 in total

1.  Muscle substrate utilization from alveolar gas exchange in trained cyclists.

Authors:  M Riley; K Wasserman; P C Fu; C B Cooper
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

2.  Serum Bicarbonate as a Surrogate for pH in Hemodialysis: A Pilot Study.

Authors:  Tyler B Woodell; Dena E Rifkin; David H Ellison; Dan Negoianu; Jessica W Weiss
Journal:  Kidney Med       Date:  2019-10-22

3.  Comparison of values of traditionally measured venous bicarbonate with calculated arterial bicarbonate in intensive care unit patients of a hospital in a third-world country.

Authors:  Waheeda Nargis; Akm Shafiqur Rahman; Borhan Uddin Ahamed; Md Zakir Hossain
Journal:  Niger Med J       Date:  2014-07

4.  Evaluating the effect of sample type on American alligator (Alligator mississippiensis) analyte values in a point-of-care blood analyser.

Authors:  Matthew T Hamilton; John W Finger; Megan E Winzeler; Tracey D Tuberville
Journal:  Conserv Physiol       Date:  2016-01-08       Impact factor: 3.079

5.  Comparison of bicarbonate values from venous blood gas and chemistry panels measured at the time of diagnosis and resolution of diabetes ketoacidosis.

Authors:  Poorani Nallam Goundan; Devina Luhur Willard; Ayse Sahin-Efe; Shu-Ling Liang Fan; Sara Michelle Alexanian
Journal:  J Clin Transl Endocrinol       Date:  2019-08-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.