| Literature DB >> 21237286 |
Katalin Kovács1, Lívia Anna, Péter Rudnai, Bernadette Schoket.
Abstract
Bulky DNA adducts are widely used as biomarkers of human exposure to complex mixtures of environmental genotoxicants including polycyclic aromatic hydrocarbons. The 32P-postlabelling method is highly sensitive for the detection of bulky DNA adducts, but its relatively low throughput poses limits to its use in large-scale molecular epidemiological studies. The objectives of this study were to compare the impact of DNA-sample preparation with a commercial DNA-isolation kit or with the classical phenol-extraction procedure on the measurement of bulky DNA adducts by 32P-postlabelling, and to increase the throughput of the 32P-postlabelling method--whilst maintaining radio-safety--by reducing the radioisotope requirement per sample. The test DNA samples were prepared from MCF-7 cells treated with benzo[a]pyrene and from human peripheral blood lymphocytes, buffy coat, and peripheral lung tissue. The modified 32P-postlabelling procedure involved an evaporation-to-dryness step after the enzymatic digestions of the DNA, and radio-labelling with a reduced amount of [γ-32P]ATP substrate in a reduced reaction volume compared with the regular method. Higher levels of DNA adducts were measured in the MCF-7 cells and in the lung-tissue samples after isolation with the kit than after solvent extraction. A seven-fold higher level of adducts was detected in the buffy-coat DNA samples isolated with the kit than with the phenol extraction procedure (p<0.001). Reduction of the amount of [γ-32P]ATP from 50 μCi to 25 μCi (>6000 Ci/mmol specific radioactivity) per sample in the modified 32P-postlabelling procedure was generally applicable without loss of adduct recovery for all test samples prepared with both DNA isolation methods. The difference between the bulky DNA-adduct levels resulting from the two DNA-isolation procedures requires further systematic investigation. The modified 32P-postlabelling procedure allows a 50% reduction of radioisotope requirement per sample, which facilitates increased throughput of the assay whilst maintaining radio-safety.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21237286 DOI: 10.1016/j.mrgentox.2010.12.012
Source DB: PubMed Journal: Mutat Res ISSN: 0027-5107 Impact factor: 2.433