Literature DB >> 21236406

Evaluation of intraocular lens tilt with anterior segment optical coherence tomography.

Dhivya Ashok Kumar1, Amar Agarwal, Gaurav Prakash, Soosan Jacob, Yoga Saravanan, Athiya Agarwal.   

Abstract

PURPOSE: To determine the ability of anterior segment optical coherence tomography (OCT) to detect intraocular lens (IOL) tilt evaluation in relation to the limbus.
DESIGN: Observational case series.
METHODS: The IOL position of 123 eyes of 92 patients was examined with anterior segment OCT (Carl Zeiss Meditec, Dublin, California, USA). All eyes underwent uneventful phacoemulsification with the IOL in the bag. Images were obtained in 4 axes (180 to 0 degrees, 225 to 45 degrees, 315 to 135 degrees, and 270 to 90 degrees). Using MatLab software version 7.1 (Mathworks), the OCT images were analyzed. The distance between the iris margin and the anterior surface of IOL, the slope ratio between IOL and limbus, and the angle (θ; position of IOL with reference to the limbus) were determined and were correlated with the astigmatism and vision.
RESULTS: The mean slope of the limbus and the IOL in all axes was 0.003 ± 0.09 and -0.002 ± 0.12, respectively. The average slope ratio was 1.1 ± 1 (range, -2.09 to 3.82) and the angle (θ) was 1.52 ± 0.9 degrees (range, 0.04 to 3.6 degrees). The mean ocular residual astigmatism was 0.2379 ± 0.469 diopters. There was no significant correlation of ocular residual astigmatism with slope ratio (r = -0.171; P = .060) and slope angle (r = -0.132; P = .147). There was significant correlation of ocular residual astigmatism with total astigmatism (r=0.602, p=0.000). The mean distances between the iris margin and the anterior surface of IOL at the pupillary plane were 0.80 ± 0.6 mm and 0.83 ± 0.57 mm, respectively.
CONCLUSIONS: The normal in-the-bag IOL maintains an angle with reference to the limbus and a slope ratio without causing a significant tilt. Anterior segment OCT can be used as an alternative in IOL tilt evaluation by the analysis of its position in relation to the limbus.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21236406     DOI: 10.1016/j.ajo.2010.09.013

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  18 in total

1.  The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation.

Authors:  Burcu Kemer Atik; Cigdem Altan; Alper Agca; Asli Kirmaci; Yusuf Yildirim; Selim Genc; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2019-11-23       Impact factor: 2.031

2.  Angle alpha as predictor for improving patient satisfaction with multifocal intraocular lenses?

Authors:  Andrzej Grzybowski; Timo Eppig
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-01-04       Impact factor: 3.117

3.  Reinforced scleral fixation of foldable intraocular lens by double sutures: comparison with intrascleral intraocular lens fixation.

Authors:  Yodpong Chantarasorn; Settapong Techalertsuwan; Pongsavit Siripanthong; Anurak Tamerug
Journal:  Jpn J Ophthalmol       Date:  2018-02-20       Impact factor: 2.447

4.  Assessment of long-term intraocular lens (IOL) decentration and tilt in eyes with pseudoexfoliation syndrome (PES) following cataract surgery.

Authors:  Michael Burgmüller; Kata Mihaltz; Christopher Schütze; Bernhard Angermann; Veronika Vécsei-Marlovits
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-10-01       Impact factor: 3.117

5.  Toric markers-assisted implantation of the scleral-fixated intraocular lens.

Authors:  Hu-Ping Song; Bing-Yu Tian; Jing Peng
Journal:  Int J Ophthalmol       Date:  2016-09-18       Impact factor: 1.779

6.  Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation.

Authors:  Teruaki Tokuhisa; Tomoyuki Watanabe; Akira Watanabe; Tadashi Nakano
Journal:  Int Ophthalmol       Date:  2022-01-22       Impact factor: 2.031

7.  Intraocular lens implantation in the absence of capsular support: scleral fixation.

Authors:  Michael Tsatsos; Georgios Vartsakis; Ioannis Athanasiadis; Marilita Moschos; Soosan Jacob
Journal:  Eye (Lond)       Date:  2022-03-24       Impact factor: 4.456

8.  Full OCT anterior segment biometry: an application in cataract surgery.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Sonia Durán; Miriam Velasco-Ocana; Judith Birkenfeld; Alberto de Castro; Ignacio Jiménez-Alfaro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2013-01-31       Impact factor: 3.732

9.  IOL tilt and decentration estimation from 3 dimensional reconstruction of OCT image.

Authors:  Xiaogang Wang; Jing Dong; Xiaoliang Wang; Qiang Wu
Journal:  PLoS One       Date:  2013-03-15       Impact factor: 3.240

10.  Research on calculation of the IOL tilt and decentration based on surface fitting.

Authors:  Lin Li; Ke Wang; Yan Yan; Xudong Song; Zhicheng Liu
Journal:  Comput Math Methods Med       Date:  2013-07-14       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.