Literature DB >> 21233001

Hemodynamic effect of Neuroform stent on intimal hyperplasia and thrombus formation in a carotid aneurysm.

Liang-Der Jou1, Michel E Mawad.   

Abstract

Stents play an important role in management of cerebral aneurysms. A stent reconstructs the parent artery, assists coil embolization, and decreases flow activity within an aneurysm. However, an in-stent stenosis often occurs within the stented artery and compromises the circulation at the parent artery. Hemodynamic basis of re-stenoses from aneurysm stenting is not fully understood. An 8mm cavernous carotid aneurysm with a wide neck was treated by a Neuroform stent first and by coils five weeks later. A comparison of the difference in morphology during this five-week period reveals the presence of intimal hyperplasia in the internal carotid artery, 1.3mm thick at the proximal end and 1mm at the distal end of the stent, and 1mm thick thrombus at the postero-inferior side of the aneurysm. Computational fluid dynamic analyses show that the site of intimal hyperplasia is exposed to low wall shear with high oscillatory shear index (OSI), and the location of thrombus is subject to high OSI. Intimal hyperplasia and thrombus occur at comparable rates, but at different hemodynamic conditions; however, both prefer regions with high OSIs.
Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21233001     DOI: 10.1016/j.medengphy.2010.12.013

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  The effect of intracranial stent implantation on the curvature of the cerebrovasculature.

Authors:  R M King; J-Y Chueh; I M J van der Bom; C F Silva; S L Carniato; G Spilberg; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-26       Impact factor: 3.825

2.  The 'Sphere': A Dedicated Bifurcation Aneurysm Flow-Diverter Device.

Authors:  Thomas Peach; J Frederick Cornhill; Anh Nguyen; Howard Riina; Yiannis Ventikos
Journal:  Cardiovasc Eng Technol       Date:  2014-08-26       Impact factor: 2.495

3.  Is there an association between flow diverter fish mouthing and delayed-type hypersensitivity to metals?-a case-control study.

Authors:  Naci Kocer; Prabath Kumar Mondel; Elif Yamac; Ayse Kavak; Osman Kizilkilic; Civan Islak
Journal:  Neuroradiology       Date:  2017-09-05       Impact factor: 2.804

4.  Safety and efficacy of neuroform for treatment of intracranial aneurysms: a prospective, consecutive, French multicentric study.

Authors:  J C Gentric; A Biondi; M Piotin; C Mounayer; K Lobotesis; A Bonafé; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2013-01-24       Impact factor: 3.825

5.  A Virtual Comparison of the eCLIPs Device and Conventional Flow-Diverters as Treatment for Cerebral Bifurcation Aneurysms.

Authors:  T W Peach; D Ricci; Y Ventikos
Journal:  Cardiovasc Eng Technol       Date:  2019-07-08       Impact factor: 2.495

6.  Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms.

Authors:  T W Peach; K Spranger; Y Ventikos
Journal:  Ann Biomed Eng       Date:  2015-08-04       Impact factor: 3.934

  6 in total