OBJECTIVE: We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. MATERIALS AND METHODS: Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. RESULTS: Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4; mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. CONCLUSION: The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon.
OBJECTIVE: We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. MATERIALS AND METHODS: Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. RESULTS: Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4; mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. CONCLUSION: The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon.
Authors: Shaji Sebastian; Sean Johnston; Tony Geoghegan; William Torreggiani; Martin Buckley Journal: Am J Gastroenterol Date: 2004-10 Impact factor: 10.864
Authors: A Mainar; M A De Gregorio Ariza; E Tejero; R Tobío; E Alfonso; I Pinto; M Herrera; J A Fernández Journal: Radiology Date: 1999-01 Impact factor: 11.105
Authors: Alessandro Repici; Douglas G Adler; Christopher M Gibbs; Alberto Malesci; Paoletta Preatoni; Todd H Baron Journal: Gastrointest Endosc Date: 2007-11 Impact factor: 9.427
Authors: Honsoul Kim; Seung Hyoung Kim; Sun Young Choi; Kwang-Hun Lee; Jong Yoon Won; Do Yun Lee; Jong Tae Lee Journal: J Vasc Interv Radiol Date: 2008-10-08 Impact factor: 3.464