Literature DB >> 18845454

Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

Honsoul Kim1, Seung Hyoung Kim, Sun Young Choi, Kwang-Hun Lee, Jong Yoon Won, Do Yun Lee, Jong Tae Lee.   

Abstract

PURPOSE: To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction.
MATERIALS AND METHODS: Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6).
RESULTS: Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days).
CONCLUSIONS: Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18845454     DOI: 10.1016/j.jvir.2008.08.020

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  11 in total

1.  Use of a nitinol stent to palliate a colorectal neoplastic obstruction in a dog.

Authors:  William T N Culp; Catriona M Macphail; James A Perry; Tracey D Jensen
Journal:  J Am Vet Med Assoc       Date:  2011-07-15       Impact factor: 1.936

2.  The efficacy of the coaxial technique using a 6-Fr introducer sheath in stent placement for treating the obstructions proximal to the descending colon.

Authors:  Il Soo Chang; Sang Woo Park; Dae-Yong Hwang; Moo Kyung Seong; Hee-Kyung Joh; So Young Yoon; Yo-Han Cho; Won Hyeok Choe
Journal:  Korean J Radiol       Date:  2011-01-03       Impact factor: 3.500

Review 3.  Self-expandable metallic stents in patients with stage IV obstructing colorectal cancer.

Authors:  Antonietta Lamazza; Enrico Fiori; Alberto Schillaci; Ercole DeMasi; Stefano Pontone; Antonio V Sterpetti
Journal:  World J Surg       Date:  2012-12       Impact factor: 3.352

4.  Clinical outcomes following secondary self-expandable metal stent (SEMS) insertion due to previous stent migration in malignant colorectal obstruction.

Authors:  A Ra Choi; Jin Young Yoon; Hyun Jung Lee; Hui Won Jang; Soo Jung Park; Sung Pil Hong; Tae Il Kim; Won Ho Kim; Jae Hee Cheon
Journal:  Surg Endosc       Date:  2013-03-22       Impact factor: 4.584

5.  Stenting of the colon in patients with malignant large bowel obstruction: a local experience.

Authors:  Malcolm West; Robert Kiff
Journal:  J Gastrointest Cancer       Date:  2011-09

6.  Efficacy and safety of colonic stenting for malignant disease in the elderly.

Authors:  Fergal Donnellan; Garret Cullen; Daniel Cagney; Phil O'Halloran; Gavin C Harewood; Frank E Murray; Stephen E Patchett
Journal:  Int J Colorectal Dis       Date:  2010-03-06       Impact factor: 2.571

7.  Clinical effect of double coaxial self-expandable metallic stent in management of malignant colon obstruction.

Authors:  Yoodong Won; Su Lim Lee; Young Mi Ku; Ki Tae Kim; Hye Sung Won; Chang Hyeok An
Journal:  Diagn Interv Radiol       Date:  2015 Mar-Apr       Impact factor: 2.630

8.  Fluoroscopic management of complications after colorectal stent placement.

Authors:  Jorge E Lopera; Miguel Angel De Gregorio
Journal:  Gut Liver       Date:  2010-09-10       Impact factor: 4.519

Review 9.  Role of self expandable stents in management of colorectal cancers.

Authors:  Erdinc Cetinkaya; Ahmet Bulent Dogrul; Mehmet Bulent Tirnaksiz
Journal:  World J Gastrointest Oncol       Date:  2016-01-15

Review 10.  Interventional palliative strategies for malignant bowel obstruction.

Authors:  Todd H Baron
Journal:  Curr Oncol Rep       Date:  2009-07       Impact factor: 5.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.