Literature DB >> 21220173

An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9.

Periklis A Davlouros1, Eleni Mavronasiou, Ioanna Xanthopoulou, Vasileios Karantalis, Grigorios Tsigkas, George Hahalis, Dimitrios Alexopoulos.   

Abstract

BACKGROUND: Tissue coverage and strut apposition of drug eluting stents (DES), which can be assessed with optical coherence tomography (OCT), may be associated with late stent thrombosis (LST).
METHODS: Prospective observational angiographic and OCT follow-up at 6 months post-implantation of a biolimus-A9 eluting stent (BES) vs. a paclitaxel eluting stent (PES), with biodegradable polymer carriers. The primary outcome was the percent difference of uncovered struts between BESs and PESs.
RESULTS: A maximum likelihood model was used for analysis, to account for data clustering. Sixteen patients were treated with BES (28 lesions/4530 struts) and 16 with PES (23 lesions/4450 struts). Overall, BESs compared to PESs had more uncovered [0.41% vs. 0.21%, difference estimate (DE) 0.2 (95% CI, 0.06-0.34), p=0.006], malapposed [0.18% vs. 0.04%, DE 0.14 (95% CI 0.05-0.23), p=0.003], uncovered and malapposed [0.08% vs. 0.026%, DE 0.057 (95% CI 0.015-0.1), p=0.01] and protruding struts [0.23% vs. 0.04%, DE 0.185 (95% CI 0.1-0.27), p<0.001], and significantly lower neointimal thickness (59.3 ± 28.2 μm vs. 201.7 ± 97.5, p<0.001). None of the BESs was totally covered with neointima, in contrast to 5 (21.7%) PESs (p=0.01). Thrombus was detected in 1 (3.6%) BES and 5 (21.7%) PESs (p=0.05); however, no patient experienced clinical stent thrombosis.
CONCLUSION: Between two stents with biodegradable polymer, OCT demonstrated that BESs had more uncovered and malapposed struts compared to PESs at 6 months. This difference might be partly attributed to the more potent antiproliferative properties of biolimus-A9; however, its impact on clinical outcome and on the risk of LST is yet to be determined.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21220173     DOI: 10.1016/j.ijcard.2010.12.072

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  7 in total

1.  Relationship between endothelial vasomotor function and strut coverage after implantation of drug-eluting stent assessed by optical coherence tomography.

Authors:  Hoyoun Won; Jung-Sun Kim; Dong-Ho Shin; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-13       Impact factor: 2.357

Review 2.  Optical coherence tomography: from research to practice.

Authors:  Juan Luis Gutiérrez-Chico; Eduardo Alegría-Barrero; Rodrigo Teijeiro-Mestre; Pak Hei Chan; Hiroto Tsujioka; Ranil de Silva; Nicola Viceconte; Alistair Lindsay; Tiffany Patterson; Nicolas Foin; Takashi Akasaka; Carlo di Mario
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-02-13       Impact factor: 6.875

3.  Impact of statin treatment on strut coverage after drug-eluting stent implantation.

Authors:  Yongsung Suh; Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Yonsei Med J       Date:  2015-01       Impact factor: 2.759

4.  Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents.

Authors:  Abhilash Akinapelli; Jack P Chen; Kristine Roy; Joseph Donnelly; Keith Dawkins; Barbara Huibregtse; Dongming Hou
Journal:  Curr Cardiol Rev       Date:  2017

5.  Impact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation.

Authors:  Sung-Jin Hong; Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Yonsei Med J       Date:  2015-11       Impact factor: 2.759

6.  Novel sirolimus-eluting stent Prolim® with a biodegradable polymer in the all-comers population: one year clinical results with quantitative coronary angiography and optical coherence tomography analysis.

Authors:  Jacek Bil; Robert J Gil; Adam Kern; Tomasz Pawłowski; Piotr Seweryniak; Zbigniew Śliwiński
Journal:  BMC Cardiovasc Disord       Date:  2015-11-14       Impact factor: 2.298

7.  Mobilization of progenitor cells and assessment of vessel healing after second generation drug-eluting stenting by optical coherence tomography.

Authors:  Masashi Sakuma; Takahisa Nasuno; Shichiro Abe; Syotaro Obi; Shigeru Toyoda; Isao Taguchi; Ryoichi Sohma; Ken-Ichi Inoue; Setsu Nishino; Koichi Node; Guiherme Attizzani; Hiram Bezerra; Marco Costa; Daniel Simon; Teruo Inoue
Journal:  Int J Cardiol Heart Vasc       Date:  2018-02-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.