Literature DB >> 21212075

Monte Carlo calculations on extremity and eye lens dosimetry for medical staff at interventional radiology procedures.

E Carinou1, P Ferrari, C Koukorava, S Krim, L Struelens.   

Abstract

There are many factors that can influence the extremity and eye lens doses of the medical staff during interventional radiology and cardiology procedures. Numerical simulations can play an important role in evaluating extremity and eye lens doses in correlation with many different parameters. In the present study, the first results of the ORAMED (Optimisation of Radiation protection of MEDical staff) simulation campaign are presented. The parameters investigated for their influence on eye lens, hand, wrist and leg doses are: tube voltage, filtration, beam projection, field size and irradiated part of the patient's body. The tube voltage ranged from 60 to 110 kV(p), filtration from 3 to 6 mm Al and from 0 to 0.9 mm Cu. For all projections, the results showed that doses received by the operator decreased with increasing tube voltage and filtration. The magnitude of the influence of the tube voltage and the filtration on the doses depends on the beam projection and the irradiated part of the patient's body. Finally, the influence of the field size is significant in decreasing the doses.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21212075     DOI: 10.1093/rpd/ncq573

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Seeing is believing: increasing intraoperative awareness to scattered radiation in interventional procedures by combining augmented reality, Monte Carlo simulations and wireless dosimeters.

Authors:  Nicolas Loy Rodas; Nicolas Padoy
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-02-26       Impact factor: 2.924

Review 2.  Occupational exposure to low doses of ionizing radiation and cataract development: a systematic literature review and perspectives on future studies.

Authors:  Gaël P Hammer; Ulrike Scheidemann-Wesp; Florence Samkange-Zeeb; Henryk Wicke; Kazuo Neriishi; Maria Blettner
Journal:  Radiat Environ Biophys       Date:  2013-06-27       Impact factor: 1.925

3.  Assessing Human Eye Exposure to UV Light: A Narrative Review.

Authors:  Michele Marro; Laurent Moccozet; David Vernez
Journal:  Front Public Health       Date:  2022-07-06

4.  [Assessment of the practices and knowledge among cardiologists regarding radiation protection in Tunisia].

Authors:  Rania Hammami; Abdelhamid Ben Jmaa; Amine Bahloul; Selma Charfeddine; Tarek Ellouze; Souad Mallek; Imtinene Ben Mrad; Leila Abid; Samir Kammoun; Jihen Jdidi
Journal:  Pan Afr Med J       Date:  2021-03-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.