| Literature DB >> 2121070 |
J M Shapiro1, E L Bond, J K Garman.
Abstract
We performed a prospective randomized controlled trial to assess the efficacy of a chlorhexidine dressing in reducing the microbial flora at the insertion site of epidural catheters. These catheters were used for acute pain management and were dressed either by a standardized method or with a CHX/urethane sponge composite. Microbial colonization of the catheter developed in 9 of 31 controls (29.0%) and 1 of 26 (3.8%) catheters with the CHX dressing (P less than 0.05%). The CHX dressing caused no adverse effects. The data suggest that delivery of antiseptic to the catheter wound site reduces catheter colonization with a possible reduction in the risk of epidural catheter-related infection.Entities:
Mesh:
Substances:
Year: 1990 PMID: 2121070 DOI: 10.1097/00000542-199010000-00007
Source DB: PubMed Journal: Anesthesiology ISSN: 0003-3022 Impact factor: 7.892