Literature DB >> 21208241

Initial single-center experience of a quadripolar pacing lead for cardiac resynchronization therapy.

Anoop K Shetty1, Simon G Duckett, Julian Bostock, Debashis Roy, Matthew Ginks, Shoaib Hamid, Eric Rosenthal, Reza Razavi, Christopher Aldo Rinaldi.   

Abstract

BACKGROUND: The Quartet model 1458Q (St. Jude Medical, Sylmar, CA, USA) lead is a quadripolar left ventricular (LV) lead with pace/sense capability from four electrodes (tip and three rings). The lead is capable of pacing in 10 different configurations rather than the three that are available in conventional bipolar pacing leads. We describe a single-center initial experience of the use of this lead in patients undergoing cardiac resynchronization therapy (CRT).
METHODS: Twenty-eight patients for a CRT with cardiac defibrillator were implanted between October 2009 and May 2010 with a Quartet lead . Lead position, pacing parameters, stability, complications, and presence of phrenic nerve stimulation (PNS) data were collected at implant and predischarge. Follow-up data were collected at 15 ± 8 weeks for all patients.
RESULTS: A Quartet lead was successfully implanted in 96% (27/28) of patients (age 61 ± 15 years; 82% male; ischemic etiology 50%; mean left ventricular [LV] ejection fraction 25 ± 7%; left bundle branch block 68%). PNS was seen at implant in 11 patients (41%) with at least one vector. In eight of these cases (72%), the need for lead repositioning was averted by programming LV pacing utilizing the additional vectors available with the Quartet lead.
CONCLUSION: These initial data suggest that pacing with the Quartet lead is associated with a high implant success rate and stable pacing parameters acutely and at short-term follow-up. The 10 LV pacing vectors available with this lead may allow PNS and capture threshold problems to be easily overcome. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21208241     DOI: 10.1111/j.1540-8159.2010.03003.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  18 in total

Review 1.  Updates in Cardiac Resynchronization Therapy for Chronic Heart Failure: Review of Multisite Pacing.

Authors:  Antonios P Antoniadis; Ben Sieniewicz; Justin Gould; Bradley Porter; Jessica Webb; Simon Claridge; Jonathan M Behar; Christopher Aldo Rinaldi
Journal:  Curr Heart Fail Rep       Date:  2017-10

2.  Elimination of phrenic nerve stimulation occurring during CRT: follow-up in patients implanted with a novel quadripolar pacing lead.

Authors:  Paresh A Mehta; Anoop K Shetty; Mark Squirrel; Julian Bostock; C Aldo Rinaldi
Journal:  J Interv Card Electrophysiol       Date:  2011-07-21       Impact factor: 1.900

3.  Monitoring biventricular pacing parameters depending on the left ventricle lead configuration.

Authors:  Antonin Prochazka; David Korpas
Journal:  Exp Clin Cardiol       Date:  2013

4.  Limitations of chronic delivery of multi-vein left ventricular stimulation for cardiac resynchronization therapy.

Authors:  Jonathan M Behar; Julian Bostock; Matthew Ginks; Tom Jackson; Manav Sohal; Simon Claridge; Reza Razavi; Christopher Aldo Rinaldi
Journal:  J Interv Card Electrophysiol       Date:  2015-01-28       Impact factor: 1.900

5.  A Meta-Analysis Of Quadripolar Versus Bipolar Left Ventricular Leads On Post-Procedural Outcomes.

Authors:  Mohit K Turagam; Muhammad R Afzal; Sandia Iskander; Luigi Di Biase; Andrea Natale; Dhanunjaya Lakkireddy
Journal:  J Atr Fibrillation       Date:  2016-08-31

Review 6.  Phrenic nerve stimulation in cardiac resynchronization therapy.

Authors:  Ghassan Moubarak; Abdeslam Bouzeman; Jacky Ollitrault; Frederic Anselme; Serge Cazeau
Journal:  J Interv Card Electrophysiol       Date:  2014-06-17       Impact factor: 1.900

Review 7.  Multisite Pacing for Cardiac Resynchronization Therapy: Promise and Pitfalls.

Authors:  Antonios P Antoniadis; Jonathan M Behar; Simon Claridge; Tom Jackson; Manav Sohal; Christopher Aldo Rinaldi
Journal:  Curr Cardiol Rep       Date:  2016-07       Impact factor: 2.931

Review 8.  Optimizing CRT - Do We Need More Leads and Delivery Methods.

Authors:  Pieter Martens; Frederik Hendrik Verbrugge; Wilfried Mullens
Journal:  J Atr Fibrillation       Date:  2015-04-30

9.  Single-center experience of a quadripolar pacing lead for cardiac resynchronization therapy.

Authors:  Antonello Vado; Endrj Menardi; Guido Rossetti; Gianpaolo Ballari; Mauro Feola; Marco Bobbio
Journal:  J Interv Card Electrophysiol       Date:  2013-11-29       Impact factor: 1.900

10.  Developments in Cardiac Resynchronisation Therapy.

Authors:  Geoffrey F Lewis; Michael R Gold
Journal:  Arrhythm Electrophysiol Rev       Date:  2015-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.