Literature DB >> 21189081

The influence of maximum bite force on patient satisfaction and quality of life of patients wearing mandibular implant overdentures.

Onur Geckili1, Hakan Bilhan, Emre Mumcu, Necat Tuncer.   

Abstract

The treatment of edentulism with traditional complete dentures can often induce impaired masticatory function due to limited retention and stability, especially in the lower jaw. Mandibular interforaminal implants have been widely used to stabilize the dentures, consequently improving masticatory performance in edentulous individuals. The aim of the present study was to document the influence of this improved masticatory function on patient satisfaction and quality of life of patients wearing mandibular implant-supported overdentures. Sixty-two patients treated with various types of implant-supported mandibular overdentures between 2004 and 2007 were included in this retrospective study. Maximum bite force (MBF) was measured bilaterally using a device with 2 strain gauges connected to a strain gauge measurement system. All the included patients were asked to fill out visual analog scale (VAS) forms based on general and chewing satisfaction and OHIP-14 forms. Results were analyzed by the Spearman rho test. No statistically significant correlation was found between MBF values and VAS general or VAS chewing satisfaction or Oral Health Impact Profile scores (P > .05). The results indicate that MBF is not associated with the satisfaction or quality of life of implant-supported mandibular overdenture wearers.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21189081     DOI: 10.1563/AAID-JOI-D-10-00073

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Evaluation of patient satisfaction and masticatory performance in mandible single implant-assisted overdenture.

Authors:  Swati Kashyap; Sanjeev Mittal; Navneet Sharma; Urvashi Sukhija; Mohit Kamra; Nitika Gupta
Journal:  Tzu Chi Med J       Date:  2021-04-05

2.  The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material.

Authors:  Nick Polychronakis; Aspasia Sarafianou; Alcibiadis Zissis; Triantafillos Papadopoulos
Journal:  Acta Stomatol Croat       Date:  2017-12

3.  Reliability and validity of the Turkish version of oral health impact profile for edentulous subjects.

Authors:  Canan Bural; Onur Geckili; Ozge Erdogan; Kivanc Bektas-Kayhan; Suleyman Cagatay Dayan
Journal:  Eur Oral Res       Date:  2021-05-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.