Literature DB >> 21182841

Detection of two different influenza A viruses using a nitrocellulose membrane and a magnetic biosensor.

Hyo-Bong Hong1, Hans-Joachim Krause, Ki-Bong Song, Chel-Jong Choi, Myung-Ae Chung, Sung-Won Son, Andreas Offenhäusser.   

Abstract

Here we describe a new analytical method for the detection of two influenza A viruses by nitrocellulose membrane and magnetic sensors that employ a special frequency mixing technique. The combination of the nitrocellulose membrane and magnetic bead detection permits a rapid assay procedure and excludes two steps (the development of color and the stop reaction) required for usual immunochemical detection methods such as ELISA. Quantitative virus detection was performed using magnetic beads conjugated with secondary antibody. The results were compared with conventional assay methods and with a dot-blot assay with fluorescence compound (FITC). Under optimum conditions, our new assay procedure is capable of detecting picograms of virus per well. This new method combining the nitrocellulose membrane and magnetic bead detection reduces analytical time and allows stable and repeatable analyses of samples in point-of-care applications.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21182841     DOI: 10.1016/j.jim.2010.12.005

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  7 in total

Review 1.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

2.  Magnetic nanoparticles and magnetic particle spectroscopy-based bioassays: a 15 year recap.

Authors:  Kai Wu; Jinming Liu; Vinit Kumar Chugh; Shuang Liang; Renata Saha; Venkatramana D Krishna; Maxim C-J Cheeran; Jian-Ping Wang
Journal:  Nano Futures       Date:  2022-04-07

Review 3.  A Review of Membrane-Based Biosensors for Pathogen Detection.

Authors:  Remko van den Hurk; Stephane Evoy
Journal:  Sensors (Basel)       Date:  2015-06-15       Impact factor: 3.576

4.  Sensitive Aflatoxin B1 Detection Using Nanoparticle-Based Competitive Magnetic Immunodetection.

Authors:  Jan Pietschmann; Holger Spiegel; Hans-Joachim Krause; Stefan Schillberg; Florian Schröper
Journal:  Toxins (Basel)       Date:  2020-05-20       Impact factor: 4.546

5.  Detection methods for influenza A H1N1 virus with special reference to biosensors: a review.

Authors:  Ravina R; Anita Dalal; Hari Mohan; Minakshi Prasad; C S Pundir
Journal:  Biosci Rep       Date:  2020-02-28       Impact factor: 3.840

Review 6.  Nucleic Acid-Based Nanobiosensor (NAB) Used for Salmonella Detection in Foods: A Systematic Review.

Authors:  Leticia Tessaro; Adriano Aquino; Paloma de Almeida Rodrigues; Nirav Joshi; Rafaela Gomes Ferrari; Carlos Adam Conte-Junior
Journal:  Nanomaterials (Basel)       Date:  2022-02-28       Impact factor: 5.076

Review 7.  Biosensing Using Magnetic Particle Detection Techniques.

Authors:  Yi-Ting Chen; Arati G Kolhatkar; Oussama Zenasni; Shoujun Xu; T Randall Lee
Journal:  Sensors (Basel)       Date:  2017-10-10       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.