The renovation of a building will certainly affect the quality of air in the vicinity of where associated activities were undertaken, this includes the quality of air inside the building. Indoor air pollutants such as particulate matter, heavy metals, and fine fibers are likely to be emitted during renovation work. This study was conducted to determine the concentration of heavy metals, asbestos and suspended particulates in the Biology Building, at the Universiti Kebangsaan, Malaysia (UKM). Renovation activities were carried out widely in the laboratories which were located in this building. A low-volume sampler was used to collect suspended particulate matter of a diameter size less than 10 μm (PM₁₀) and an air sampling pump, fitted with a cellulose ester membrane filter, were used for asbestos sampling. Dust was collected using a small brush and scope. The concentration of heavy metals was determined through the use of inductively coupled plasma-mass spectroscopy and the fibers were counted through a phase contrast microscope. The concentrations of PM₁₀ recorded in the building during renovation action (ranging from 166 to 542 μg m⁻³) were higher than the value set by the Department of Safety and Health for respirable dust (150 μg m⁻³). Additionally, they were higher than the value of PM₁₀ recorded in indoor environments from other studies. The composition of heavy metals in PM₁₀ and indoor dust were found to be dominated by Zn and results also showed that the concentration of heavy metals in indoor dust and PM₁₀ in this study was higher than levels recorded in other similar studies. The asbestos concentration was 0.0038 ± 0.0011 fibers/cc. This was lower than the value set by the Malaysian Department of Occupational, Safety and Health (DOSH) regulations of 0.1 fibers/cc, but higher than the background value usually recorded in indoor environments. This study strongly suggests that renovation issues need to be considered seriously by relevant stakeholders within the university in order to ensure that the associated risks toward humans and indoor environment are eliminated, or where this is not feasible, minimized as far as possible.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21181256     DOI: 10.1007/s10661-010-1843-3

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  34 in total

Review 1.  Air pollution and health.

Authors:  Bert Brunekreef; Stephen T Holgate
Journal:  Lancet       Date:  2002-10-19       Impact factor: 79.321

2.  Evaluation of cleaning methods applied in home environments after renovation and remodeling activities.

Authors:  Lih-Ming Yiin; Shou-En Lu; Sulaiman Sannoh; Benjamin S Lim; George G Rhoads
Journal:  Environ Res       Date:  2004-10       Impact factor: 6.498

3.  Emission of airborne fibers from mechanically impacted asbestos-cement sheets and concentration of fibrous aerosol in the home environment in Upper Silesia, Poland.

Authors:  Jozef S Pastuszka
Journal:  J Hazard Mater       Date:  2008-06-20       Impact factor: 10.588

Review 4.  Man-made mineral fibers (MMMF): human exposures and health risk assessment.

Authors:  M Lippmann
Journal:  Toxicol Ind Health       Date:  1990-03       Impact factor: 2.273

Review 5.  The health effects of non-industrial indoor air pollution.

Authors:  Jonathan A Bernstein; Neil Alexis; Hyacinth Bacchus; I Leonard Bernstein; Pat Fritz; Elliot Horner; Ning Li; Stephany Mason; Andre Nel; John Oullette; Kari Reijula; Tina Reponen; James Seltzer; Alisa Smith; Susan M Tarlo
Journal:  J Allergy Clin Immunol       Date:  2007-12-21       Impact factor: 10.793

6.  Migration of contaminated soil and airborne particulates to indoor dust.

Authors:  David W Layton; Paloma I Beamer
Journal:  Environ Sci Technol       Date:  2009-11-01       Impact factor: 9.028

7.  Indoor air quality investigation according to age of the school buildings in Korea.

Authors:  Jongryeul Sohn; Wonho Yang; Jihwan Kim; Busoon Son; Jinchul Park
Journal:  J Environ Manage       Date:  2008-02-20       Impact factor: 6.789

8.  Relationship between indoor environment and asthma and wheeze severity among rural children and adolescents.

Authors:  Joshua A Lawson; James A Dosman; Donna C Rennie; Jeremy Beach; Stephen C Newman; Ambikaipakan Senthilselvan
Journal:  J Agromedicine       Date:  2009       Impact factor: 1.675

9.  Indoor air pollution levels in public buildings in Thailand and exposure assessment.

Authors:  Aungsiri Klinmalee; Kasama Srimongkol; Nguyen Thi Kim Oanh
Journal:  Environ Monit Assess       Date:  2008-08-19       Impact factor: 2.513

10.  Microenvironmental analysis of residential exposure to chromium-laden wastes in and around New Jersey homes.

Authors:  P J Lioy; N C Freeman; T Wainman; A H Stern; R Boesch; T Howell; S I Shupack
Journal:  Risk Anal       Date:  1992-06       Impact factor: 4.000

View more
  4 in total

1.  Pollution distribution and health risk assessment of heavy metals in indoor dust in Anhui rural, China.

Authors:  Yuesheng Lin; Fengman Fang; Fei Wang; Minglu Xu
Journal:  Environ Monit Assess       Date:  2015-08-12       Impact factor: 2.513

2.  Metals compositions of indoor PM2.5, health risk assessment, and birth outcomes in Lanzhou, China.

Authors:  Yaqun Zhang; Suzhen Cao; Xiaoying Xu; Jie Qiu; Mingxia Chen; Dennis Wang; Donghong Guan; Chengyuan Wang; Xiao Wang; Bowen Dong; Huang Huang; Nan Zhao; Lan Jin; Yana Bai; Xiaoli Duan; Qing Liu; Yawei Zhang
Journal:  Environ Monit Assess       Date:  2016-05-04       Impact factor: 2.513

Review 3.  Recent Scientific Evidence Regarding Asbestos Use and Health Consequences of Asbestos Exposure.

Authors:  Manuela Valenzuela; Margarita Giraldo; Sonia Gallo-Murcia; Juliana Pineda; Laura Santos; Juan Pablo Ramos-Bonilla
Journal:  Curr Environ Health Rep       Date:  2016-12

4.  Assessment of Individual-Level Exposure to Airborne Particulate Matter during Periods of Atmospheric Thermal Inversion.

Authors:  Rok Novak; Johanna Amalia Robinson; Tjaša Kanduč; Dimosthenis Sarigiannis; David Kocman
Journal:  Sensors (Basel)       Date:  2022-09-20       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.