Literature DB >> 21179294

The effect on respiratory mechanics when using a Jackson surgical table in the prone position during spinal surgery.

Yoontae Nam1, Ann Misun Yoon, Yoon Hee Kim, Seok Hwa Yoon.   

Abstract

BACKGROUND: Respiratory dynamics may be monitored and evaluated indirectly by measuring the peak inspiratory pressure and plateau pressure. In this study, the respiratory dynamics of patients undergoing spinal surgery using a Jackson surgical table were observed with a device after converting their position from supine to prone. The effects of the dynamic compliance and airway resistance were observed from the changes in peak inspiratory pressure and plateau.
METHODS: Twenty five patients were selected as subjects scheduled to undergo lumbar spine surgery. After intubation, the patients were ventilated mechanically with a tidal volume of 10 ml/kg and a respiration rate of 10/min. Anesthesia was maintained with sevoflurane 1.5%, nitrous oxide 2 L/min and oxygen 2 L/min. The peak inspiratory pressure, plateau pressure, resistance, compliance, arterial oxygen tension, carbon dioxide tension, heart rate and arterial blood pressure were measured at 10 minutes after the induction of anesthesia. These parameters were measured again 10 minutes after placing the patient in the prone position.
RESULTS: The prone position did not significantly affect the arterial oxygen tension, carbon dioxide tension, blood pressure and heart rate, but significantly increased the peak inspiratory pressure and resistance and decreased the dynamic compliance.
CONCLUSIONS: The peak inspiratory pressure was increased using a Jackson surgical table to minimize the abdominal pressure when converting from the supine to prone position. This might be due to a decrease in lung and chest compliance as well as an increase in airway resistance.

Entities:  

Keywords:  Airway resistance; Dynamic compliance; Jackson surgical table; Peak inspiratory pressure; Prone position; Respiratory mechanics

Year:  2010        PMID: 21179294      PMCID: PMC2998652          DOI: 10.4097/kjae.2010.59.5.323

Source DB:  PubMed          Journal:  Korean J Anesthesiol        ISSN: 2005-6419


  21 in total

1.  Changes in lung thorax compliance during orthopedic surgery.

Authors:  S LYNCH; L BRAND; A LEVY
Journal:  Anesthesiology       Date:  1959 May-Jun       Impact factor: 7.892

2.  Hemodynamic effect of the prone position during anesthesia.

Authors:  M Yokoyama; W Ueda; M Hirakawa; H Yamamoto
Journal:  Acta Anaesthesiol Scand       Date:  1991-11       Impact factor: 2.105

3.  Respiratory function and ribcage contribution to ventilation in body positions commonly used during anesthesia.

Authors:  A B Lumb; J F Nunn
Journal:  Anesth Analg       Date:  1991-10       Impact factor: 5.108

4.  A simple automated method for measuring pressure-volume curves during mechanical ventilation.

Authors:  Q Lu; S R Vieira; J Richecoeur; L Puybasset; P Kalfon; P Coriat; J J Rouby
Journal:  Am J Respir Crit Care Med       Date:  1999-01       Impact factor: 21.405

5.  The effect of four different surgical prone positions on cardiovascular parameters in healthy volunteers.

Authors:  R Wadsworth; J M Anderton; A Vohra
Journal:  Anaesthesia       Date:  1996-09       Impact factor: 6.955

Review 6.  Prone position in acute respiratory distress syndrome.

Authors:  P Pelosi; L Brazzi; L Gattinoni
Journal:  Eur Respir J       Date:  2002-10       Impact factor: 16.671

7.  Regional distribution of ventilation and perfusion as a function of body position.

Authors:  K Kaneko; J Milic-Emili; M B Dolovich; A Dawson; D V Bates
Journal:  J Appl Physiol       Date:  1966-05       Impact factor: 3.531

8.  Unexpected blood clot-induced acute airway obstruction in a patient with inactive pulmonary tuberculosis during lumbar spine surgery in the prone position--a case report.

Authors:  Jui-An Lin; Chih-Shung Wong; Chen-Hwan Cherng
Journal:  Acta Anaesthesiol Taiwan       Date:  2005-06

9.  Pulmonary mechanics during general anaesthesia. The influence of mechanical irritation on the airway.

Authors:  S Dohi; M I Gold
Journal:  Br J Anaesth       Date:  1979-03       Impact factor: 9.166

10.  The prone positioning during general anesthesia minimally affects respiratory mechanics while improving functional residual capacity and increasing oxygen tension.

Authors:  P Pelosi; M Croci; E Calappi; M Cerisara; D Mulazzi; P Vicardi; L Gattinoni
Journal:  Anesth Analg       Date:  1995-05       Impact factor: 5.108

View more
  6 in total

1.  Prone position [18F]FDG PET/CT to reduce respiratory motion artefacts in the evaluation of lung nodules.

Authors:  Hyung Ju Lee; Hye Joo Son; Mijin Yun; Jung Won Moon; Yoo Na Kim; Ji Young Woo; Suk Hyun Lee
Journal:  Eur Radiol       Date:  2021-04-14       Impact factor: 5.315

2.  The Effect of Pressure-Controlled Ventilation and Volume-Controlled Ventilation in Prone Position on Pulmonary Mechanics and Inflammatory Markers.

Authors:  Hasan Şenay; Remziye Sıvacı; Serdar Kokulu; Buğra Koca; Elif Doğan Bakı; Yüksel Ela
Journal:  Inflammation       Date:  2016-08       Impact factor: 4.092

3.  Relationship Between Respiratory Dynamics and Body Mass Index in Patients Undergoing General Anesthesia with Laryngeal Mask Airway (LMA) and Comparison Between Lithotomy and Supine Positions.

Authors:  Xiao Zhao; Shiwei Huang; Zhaomin Wang; Lianhua Chen; Shitong Li
Journal:  Med Sci Monit       Date:  2016-08-01

4.  Comparative study of the Ambu® AuraOnce™ laryngeal mask and endotracheal intubation in anesthesia airway management during neurosurgery.

Authors:  Qiaoyun Zhang; Yongxing Sun; Baoguo Wang; Shuangyan Wang; Feng Mu; Yunxin Zhang
Journal:  J Int Med Res       Date:  2020-02       Impact factor: 1.671

5.  Effects of ventilation mode type on intra-abdominal pressure and intra-operative blood loss in patients undergoing lumbar spine surgery: A randomised clinical study.

Authors:  Sandeep Kundra; Rekha Gupta; Neeru Luthra; Mehak Dureja; Sunil Katyal
Journal:  Indian J Anaesth       Date:  2021-03-20

6.  Equal Ratio Ventilation Reduces Blood Loss During Posterior Lumbar Interbody Fusion Surgery.

Authors:  Hye Bin Kim; Tae Dong Kweon; Chul Ho Chang; Ji Young Kim; Kyung Sub Kim; Ji Young Kim
Journal:  Spine (Phila Pa 1976)       Date:  2021-08-15       Impact factor: 3.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.