Intermediate-term results of the Ex-PRESS miniature glaucoma implant under a scleral flap in previously operated eyes.

Dara Lankaranian1, M Reza Razeghinejad, Arun Prasad, Ghasem Fakhraie, Daniel J Freitas, Parul Ichhpujani, Marlene R Moster.   

Abstract

BACKGROUND: To report the safety and efficacy of Ex-PRESS(TM) miniature glaucoma implant under a scleral flap in patients with previous ocular surgeries.
DESIGN: Retrospective, non-comparative case series from a tertiary care hospital. PARTICIPANTS: Patients with previous cataract or failed glaucoma surgeries who had undergone implantation of the Ex-PRESS(TM) miniature glaucoma implant (R-50 and T-50), under a scleral flap, with a minimum of 1-year postoperative follow up.
METHODS: For postoperative outcome, success was defined as complete if intraocular pressure (IOP) was 5-21 mmHg without medication or surgical intervention, and qualified if intraocular pressure was within the same range with glaucoma medication. To compare the outcome between patients who had previous trabeculectomy or cataract surgery the definition of success was intraocular pressure of 5-15 mmHg. MAIN OUTCOME MEASURES: Intraocular pressure, number of antiglaucoma drugs, visual acuity and complications.
RESULTS: One hundred eyes (100 patients; mean age: 77.4 years) with a mean follow-up period of 27 ± 13.2 months (range: 12-66) were considered. Success was complete in 60 (60%) and qualified in 24 (24%) eyes. The mean preoperative IOP of 27.7 ± 9.2 mmHg (range: 14-52 mmHg) with 2.73 ± 1.1 drugs declined to 14.02 ± 5.1 mmHg with 0.72 ± 1.06 drugs at the last follow up (P < 0.0001). Causes of failure were uncontrolled intraocular pressure (11%), bleb needling (4%) and persistent hypotony (1%). The probability of success in the patients with previous cataract surgery and trabeculectomy at 3 years was 60.6% and 50.9%, respectively.
CONCLUSIONS: The Ex-PRESS(TM) implant under scleral flap was a safe and effective glaucoma surgery in the eyes with prior ocular surgery.
© 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Mesh:

Year:  2011        PMID: 21176040     DOI: 10.1111/j.1442-9071.2010.02481.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  10 in total

1.  Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma.

Authors:  Kyoko Ishida; Naoya Moroto; Kazuhiro Murata; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2017-04-03       Impact factor: 2.447

Review 2.  Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device.

Authors:  C Mariotti; E Dahan; M Nicolai; L Levitz; S Bouee
Journal:  Eye (Lond)       Date:  2013-11-15       Impact factor: 3.775

3.  Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination.

Authors:  Mohammad A Rashad
Journal:  Clin Ophthalmol       Date:  2012-12-28

Review 4.  Standard Trabeculectomy and Ex-PRESS Miniature Glaucoma Shunt: A Comparative Study and Literature Review.

Authors:  Elad Moisseiev; Eran Zunz; Rotem Tzur; Shimon Kurtz; Gabi Shemesh
Journal:  J Glaucoma       Date:  2015-08       Impact factor: 2.503

5.  Conventional trabeculectomy versus trabeculectomy with the Ex-PRESS® mini-glaucoma shunt: differences in postoperative interventions.

Authors:  Naoki Tojo; Mitsuya Otsuka; Atsushi Hayashi
Journal:  Clin Ophthalmol       Date:  2018-04-03

6.  Evaluation of Early Postoperative Intraocular Pressure for Success after Ex-Press Surgery.

Authors:  Naoki Tojo; Atsushi Hayashi; Mitsuya Otsuka
Journal:  J Curr Glaucoma Pract       Date:  2019 May-Aug

Review 7.  EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability.

Authors:  Jessica E Chan; Peter A Netland
Journal:  Med Devices (Auckl)       Date:  2015-09-02

8.  Subconjunctival bevacizumab to augment trabeculectomy with mitomycin C in the management of failed glaucoma surgery.

Authors:  Ahmed M Saeed; Tarek Tawfeek AboulNasr
Journal:  Clin Ophthalmol       Date:  2014-09-15

9.  Surgical treatment of neovascular glaucoma with Ex-PRESS glaucoma shunt: Case report.

Authors:  Teng-Chieh Yu; Gow-Lieng Tseng; Chun-Chen Chen; Shiow-Wen Liou
Journal:  Medicine (Baltimore)       Date:  2017-09       Impact factor: 1.889

Review 10.  Evolution of Glaucoma Surgery in the Last 25 Years.

Authors:  Laura Bar-David; Eytan Z Blumenthal
Journal:  Rambam Maimonides Med J       Date:  2018-07-30
  10 in total