Literature DB >> 21173496

Long-term outcome of coil occlusion in patients with patent ductus arteriosus.

Hidemi Takata1, Takashi Higaki, Hisashi Sugiyama, Masataka Kitano, Eiichi Yamamoto, Takeshi Nakano, Mitsugi Nagashima, Fumiaki Shikata, Hideshi Tomita, Satoshi Yazaki, Isao Shiraishi, Eiichi Ishii.   

Abstract

BACKGROUND: Coil occlusion has been widely indicated for the closure of patent ductus arteriosus (PDA). Although many reports have shown the efficacy and safety of coil occlusion, the long-term outcome in patients remains controversial. Here, we analyzed the long-term outcome of coil occlusion in patients with PDA in Japan. METHODS AND
RESULTS: We collected the longitudinal data of patients who underwent coil occlusion between 1995 and 2009. A total of 310 coil occlusions were performed in 298 patients with PDA. The median minimum duct diameter was 1.4mm. Successful coil occlusion was achieved in 286 patients (96.0%), and total adverse events were seen in only 28 cases (9.0%). The median follow-up period was 50 months. The occlusion rates at 1 month, 6 months, 1 year, 2 years and 5 years were 90.1%, 94.4%, 97.4%, 97.8% and 97.8%, respectively. Patients with a large PDA (≥4mm) showed a higher rate of residual leakage than those with a small (<2mm) or moderate (2-4mm) PDA (P=0.004). Patients who underwent this procedure in the early study period also showed a higher rate of residual leakage than those in the late study period.
CONCLUSIONS: Coil occlusion is an effective procedure for patients with PDA. Our data indicate that the long-term outcome is promising without any adverse events.

Entities:  

Mesh:

Year:  2010        PMID: 21173496     DOI: 10.1253/circj.cj-10-0453

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  4 in total

1.  When Can We Release the Amplatzer Ductal Occluder (ADO) Safely?

Authors:  Mehdi Ghaderian; Mahmood Merajie; Hodjjat Mortezaeian; Mohammad Yoosef Aarabi Moghadam
Journal:  J Tehran Heart Cent       Date:  2013-10-28

2.  Transcatheter Closure Versus Repeat Surgery for the Treatment of Postoperative Left-to-Right Shunts: A Single Center 15-Year Experience.

Authors:  Xinghua Gu; Qiuwang Zhang; Hourong Sun; Jianchun Fei; Xiquan Zhang; Michael J Kutryk
Journal:  Cardiol Res       Date:  2017-12-22

3.  Follow-Up Results of Device Occlusion of Patent Ductus Arteriosus.

Authors:  Hamid Amoozgar; Sara Salehi; Pouya Farhadi; Mohammad Reza Edraki; Mohammad Borzoee; Gholamhossein Ajami; Sirous Cheriki; Hamid Mohammadi
Journal:  Iran J Pediatr       Date:  2016-05-10       Impact factor: 0.364

4.  A rare case of patent ductus arteriosus diagnosed during coronary artery bypass grafting operation in a 73-year-old man.

Authors:  Ahmad Amouzeshi; Bibifatemeh Shakhsemampour; Mahmoud Ganjifard
Journal:  ARYA Atheroscler       Date:  2019-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.