Literature DB >> 21164428

Measurement of glycated hemoglobin and glycated albumin in umbilical cord: evaluation of the glycemic control indicators in neonates.

M Koga1, J Murai, H Saito, Y Yamada, T Mori, S Suno, K Takeuchi, S Suzuki, K Fujieda, S Kasayama.   

Abstract

OBJECTIVE: As neonatal blood contains a high proportion of fetal hemoglobin (HbF), it is difficult to use high-performance liquid chromatography (HPLC) method, latex-immunoturbidimetry (LA) method and enzymatic methods, which determine hemoglobin A(1C) (HbA(1C)) in order to provide the glycemic control indicators of neonates. In this study, we evaluated glycated hemoglobin (GHb) and glycated albumin (GA) as appropriate indicators of the glycemic control in the neonatal period. STUDY
DESIGN: Umbilical cord blood samples collected during delivery were subjected to measurements of GHb (HPLC methods using two different instruments, LA method, enzymatic method and affinity method) and serum GA. RESULT: HbA(1C) levels determined by the HPLC method, the LA method and the enzymatic method were as low as <3.0% in all the cases. Although GHb determined by the affinity method was 3.6 ± 0.2%, this method may not measure accurately the values of glycated HbF plus glycated HbA. Serum GA was 9.4 ± 1.1%.
CONCLUSION: We speculate that serum GA, but not GHb, could be used as glycemic control indicators in neonates.

Mesh:

Substances:

Year:  2010        PMID: 21164428     DOI: 10.1038/jp.2010.144

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  4 in total

1.  Glycated albumin but not HbA1c reflects glycaemic control in patients with neonatal diabetes mellitus.

Authors:  S Suzuki; M Koga; S Amamiya; A Nakao; K Wada; K Okuhara; S Hayano; A R Sarhat; H Takahashi; K Matsuo; Y Tanahashi; K Fujieda
Journal:  Diabetologia       Date:  2011-06-05       Impact factor: 10.122

2.  Development of filter paper hemoglobin A1c assay applicable to newborn screening.

Authors:  Allison J Pollock; David B Allen; Donald Wiebe; Jens Eickhoff; Michael MacDonald; Mei Baker
Journal:  Clin Chim Acta       Date:  2016-03-23       Impact factor: 3.786

Review 3.  Glycemic control indicators in patients with neonatal diabetes mellitus.

Authors:  Shigeru Suzuki; Masafumi Koga
Journal:  World J Diabetes       Date:  2014-04-15

4.  Correlation between hyperglycemia and glycated albumin with retinopathy of prematurity.

Authors:  Ana C Almeida; Gabriela A Silva; Gabriele Santini; Margarida Brízido; Miguel Correia; Constança Coelho; Luís Miguel Borrego
Journal:  Sci Rep       Date:  2021-11-16       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.