Literature DB >> 21164353

Comparative RNA quantification of HIV-1 group M and non-M with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 v2.0 and Abbott Real-Time HIV-1 PCR assays.

Jean-Marie Sire1, Muriel Vray, Mourad Merzouk, Jean-Christophe Plantier, Juliette Pavie, Sarah Maylin, Julie Timsit, Caroline Lascoux-Combe, Jean-Michel Molina, François Simon, Constance Delaugerre.   

Abstract

BACKGROUND: A new version of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 assay (CA/CTM v2.0) has been introduced to overcome the underquantification observed with the first version.
METHODS: We compared the Roche Cobas CA/CTM v2.0 and Abbott RealTime HIV-1 assays for HIV-1 group M and non-M viral load measurement.
RESULTS: We found a good correlation (r = 0.96) between the 2 techniques for the 260 HIV-1 group M plasma samples tested. The Roche Cobas assay gave significantly higher values than the Abbott assay, and 51 samples (20%) yielded differences greater than 0.5 log10 copies per milliliter. Conversely, 2 samples were more than 0.5 log10 copies per milliliter higher with the Abbott assay than with the Roche Cobas assay. Among the 84 samples with undetectable viral load in the Abbott assay (detection limit 40 copies/mL), 17 (20%) were detectable with the CA/CTM v2.0 assay (detection limit 20 copies/mL), with values ranging from 41 to 897 copies per milliliter. Extrapolation of the Abbott curves led to 10/17 (59%) of these samples being quantifiable. HIV-1 groups O and P were similarly quantified by the two techniques.
CONCLUSION: The results of the Roche Cobas CA/CTM v2.0 and Abbott RealTime HIV-1 assays correlate well. The new version of the CA/CTM assay shows improved sensitivity. Nevertheless, the 2 assays differ by more than 0.5 log₁₀ copies per milliliter for some samples.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21164353     DOI: 10.1097/QAI.0b013e3182099891

Source DB:  PubMed          Journal:  J Acquir Immune Defic Syndr        ISSN: 1525-4135            Impact factor:   3.731


  19 in total

1.  Upgraded Cobas Ampliprep-Cobas TaqMan version 2.0 HIV-1 RNA quantification assay versus first version: correction of underestimations.

Authors:  M Wirden; R Tubiana; S Fourati; M Thevenin; A Simon; A Canestri; Z Ait-Arkoub; C Soulie; A G Marcelin; C Katlama; V Calvez
Journal:  J Clin Microbiol       Date:  2011-05-04       Impact factor: 5.948

2.  Field evaluation of dried blood spots for routine HIV-1 viral load and drug resistance monitoring in patients receiving antiretroviral therapy in Africa and Asia.

Authors:  Marjorie Monleau; Avelin F Aghokeng; Sabrina Eymard-Duvernay; Anoumou Dagnra; Dramane Kania; Nicole Ngo-Giang-Huong; Coumba Touré-Kane; Lien X T Truong; Marie-Laure Chaix; Eric Delaporte; Ahidjo Ayouba; Martine Peeters
Journal:  J Clin Microbiol       Date:  2013-12-11       Impact factor: 5.948

3.  Ability of two commercially available assays (Abbott RealTime HIV-1 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2.0) to quantify low HIV-1 RNA Levels (<1,000 copies/milliliter): comparison with clinical samples and NIBSC working reagent for nucleic acid testing assays.

Authors:  Alessandra Amendola; Patrizia Marsella; Maria Bloisi; Federica Forbici; Claudio Angeletti; Maria R Capobianchi
Journal:  J Clin Microbiol       Date:  2014-03-26       Impact factor: 5.948

4.  Evaluation of the Aptima HIV-1 Quant Dx Assay Using Plasma and Dried Blood Spots.

Authors:  Malaya K Sahoo; Vici Varghese; Elizabeth White; Meg Winslow; David A Katzenstein; Robert W Shafer; Benjamin A Pinsky
Journal:  J Clin Microbiol       Date:  2016-08-17       Impact factor: 5.948

Review 5.  Non-M variants of human immunodeficiency virus type 1.

Authors:  Thomas Mourez; François Simon; Jean-Christophe Plantier
Journal:  Clin Microbiol Rev       Date:  2013-07       Impact factor: 26.132

6.  Cross-platform analysis of HIV-1 RNA data generated by a multicenter assay validation study with wide geographic representation.

Authors:  Cheryl Jennings; Brian Harty; Suzanne Granger; Carrie Wager; John A Crump; Susan A Fiscus; James W Bremer
Journal:  J Clin Microbiol       Date:  2012-06-12       Impact factor: 5.948

7.  A new real-time quantitative PCR for diagnosis and monitoring of HIV-1 group O infection.

Authors:  Marie Gueudin; Marie Leoz; Véronique Lemée; Fabienne De Oliveira; Aurélia Vessière; Anfumbom Kfutwah; Jean-Christophe Plantier
Journal:  J Clin Microbiol       Date:  2011-12-14       Impact factor: 5.948

8.  Single real-time reverse transcription-PCR assay for detection and quantification of genetically diverse HIV-1, SIVcpz, and SIVgor strains.

Authors:  Lucie Etienne; Sabrina Eymard-Duvernay; Avelin Aghokeng; Christelle Butel; Marjorie Monleau; Martine Peeters
Journal:  J Clin Microbiol       Date:  2012-12-19       Impact factor: 5.948

Review 9.  Past, present and future molecular diagnosis and characterization of human immunodeficiency virus infections.

Authors:  Yi-Wei Tang; Chin-Yih Ou
Journal:  Emerg Microbes Infect       Date:  2012-08-22       Impact factor: 7.163

10.  Development of real-time PCR array for simultaneous detection of eight human blood-borne viral pathogens.

Authors:  Natalia Pripuzova; Richard Wang; Shien Tsai; Bingjie Li; Guo-Chiuan Hung; Roger G Ptak; Shyh-Ching Lo
Journal:  PLoS One       Date:  2012-08-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.