Literature DB >> 21163516

The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study.

Anders Örtorp1, David Jönsson, Alaa Mouhsen, Per Vult von Steyern.   

Abstract

OBJECTIVES: This study sought to evaluate and compare the marginal and internal fit in vitro of three-unit FDPs in Co-Cr made using four fabrication techniques, and to conclude in which area the largest misfit is present.
METHODS: An epoxy resin master model was produced. The impression was first made with silicone, and master and working models were then produced. A total of 32 three-unit Co-Cr FDPs were fabricated with four different production techniques: conventional lost-wax method (LW), milled wax with lost-wax method (MW), milled Co-Cr (MC), and direct laser metal sintering (DLMS). Each of the four groups consisted of eight FDPs (test groups). The FDPs were cemented on their cast and standardised-sectioned. The cement film thickness of the marginal and internal gaps was measured in a stereomicroscope, digital photos were taken at 12× magnification and then analyzed using measurement software. Statistical analyses were performed with one-way ANOVA and Tukey's test.
RESULTS: Best fit based on the means (SDs) in μm for all measurement points was in the DLMS group 84 (60) followed by MW 117 (89), LW 133 (89) and MC 166 (135). Significant differences were present between MC and DLMS (p<0.05). The regression analyses presented differences within the parameters: production technique, tooth size, position and measurement point (p < 0.05). SIGNIFICANCE: Best fit was found in the DLMS group followed by MW, LW and MC. In all four groups, best fit in both abutments was along the axial walls and in the deepest part of the chamfer preparation. The greatest misfit was present occlusally in all specimens.
Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21163516     DOI: 10.1016/j.dental.2010.11.015

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  49 in total

1.  Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques.

Authors:  Raquel Castillo Oyagüe; Andrés Sánchez-Turrión; José Francisco López-Lozano; Javier Montero; Alberto Albaladejo; María Jesús Suárez-García
Journal:  Odontology       Date:  2011-11-11       Impact factor: 2.634

2.  Effect of Varying Layers of Two Die Spacers on Precementation Space of Full Coverage Restorations.

Authors:  Shivkumar A Mule; Shankar P Dange; Arun N Khalikar; Smita P Vaidya
Journal:  J Indian Prosthodont Soc       Date:  2014-05-14

Review 3.  Direct metal laser sintering: a digitised metal casting technology.

Authors:  K Vijay Venkatesh; V Vidyashree Nandini
Journal:  J Indian Prosthodont Soc       Date:  2013-02-05

Review 4.  3D printing in dentistry.

Authors:  A Dawood; B Marti Marti; V Sauret-Jackson; A Darwood
Journal:  Br Dent J       Date:  2015-12       Impact factor: 1.626

5.  Retention strength between veneering resin composites and laser-sintered cobalt-chromium alloy.

Authors:  Kohji Kamada; Yohsuke Taira; Tadateru Sumi; Takashi Sawase
Journal:  Odontology       Date:  2016-06-20       Impact factor: 2.634

6.  Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

Authors:  Raquel Castillo-de-Oyagüe; Andrés Sánchez-Turrión; José-Francisco López-Lozano; Alberto Albaladejo; Daniel Torres-Lagares; Javier Montero; Maria-Jesús Suárez-García
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-07-01

7.  Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems.

Authors:  Jong-Kyoung Park; Wan-Sun Lee; Hae-Young Kim; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

8.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

9.  Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Woong-Chul Kim; Hae-Young Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

10.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.