Literature DB >> 21160112

Treatment planning considerations in contrast-enhanced radiotherapy: energy and beam aperture optimization.

H M Garnica-Garza1.   

Abstract

It has been shown that the use of kilovoltage x-rays in conjunction with a contrast agent incorporated into the tumor can lead to acceptable treatment plans with regard to the absorbed dose distribution produced in the target as well as in the tissue and organs at risk surrounding it. In this work, several key aspects related to the technology and irradiation techniques necessary to clinically implement this treatment modality are addressed by means of Monte Carlo simulation. The Zubal phantom was used to model a prostate radiotherapy treatment, a challenging site due to the depth of the prostate and the presence of bony structures that must be traversed by the x-ray beam on its way to the target. It is assumed that the concentration levels of the enhancing agent present in the tumor are at or below 10 mg per 1 g of tissue. The Monte Carlo code PENELOPE was used to model a commercial x-ray tube having a tungsten target. X-ray energy spectra for several combinations of peak electron energy and added filtration were obtained. For each energy spectrum, a treatment plan was calculated, with the PENELOPE Monte Carlo code, by modeling the irradiation of the patient as 72 independent conformal beams distributed at intervals of 5° around the phantom in order to model a full x-ray source rotation. The Cimmino optimization algorithm was then used to find the optimum beam weight and energy for different treatment strategies. It is shown that for a target dose prescription of 72 Gy covering the whole tumor, the maximum rectal wall and bladder doses are kept below 52 Gy for the largest concentration of contrast agent of 10 mg per 1 g of tissue. It is also shown that concentrations of as little as 5 mg per 1 g of tissue also render dose distributions with excellent sparing of the organs at risk. A treatment strategy to address the presence of non-uniform distributions of the contrast agent in the target is also modeled and discussed.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21160112     DOI: 10.1088/0031-9155/56/2/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays.

Authors:  Piotr Zygmanski; Erno Sajo
Journal:  Br J Radiol       Date:  2015-12-07       Impact factor: 3.039

Review 2.  Nanoparticles for Radiation Therapy Enhancement: the Key Parameters.

Authors:  Paul Retif; Sophie Pinel; Magali Toussaint; Céline Frochot; Rima Chouikrat; Thierry Bastogne; Muriel Barberi-Heyob
Journal:  Theranostics       Date:  2015-06-11       Impact factor: 11.556

3.  Combined Megavoltage and Contrast-Enhanced Radiotherapy as an Intrafraction Motion Management Strategy in Lung SBRT.

Authors:  Daniel A Coronado-Delgado; Héctor M Garnica-Garza
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.