Literature DB >> 21159372

Evaluation of the integrity of dental sealants by optical coherence tomography.

Ana K S Braz1, Carlos M Aguiar, Anderson S L Gomes.   

Abstract

OBJECTIVES: The purpose of the present research was to demonstrate images of failures into the structure of pit and fissure sealants using optical coherence tomography (OCT).
METHODS: Five human third molars were selected and the sealant ALPHA SEAL LIGHT/DFL was applied according to the manufacturer instructions. For evaluation of the structure of pit and fissure sealants, twenty OCT images of each tooth were performed before and after application of sealant. A total of 200 images were evaluated. A home built spectral OCT system used was operating in spectral domain (SD-OCT), at 840 nm and a measured spatial resolution of 10 μm. The system is based on the Michelson interferometer set-up and is controlled by the software OCT 800--Complex Square/LabView, that collects data and generates the image. The occlusal surfaces were scanned in a bucco-lingual direction and tomographic images parallel to long axis of tooth were obtained. After the achievement of the images by OCT, the crown of each tooth was sectioned in a occlusogingival direction (buccolingually). Images from each section were obtained and evaluated by an optical microscope. OCT and microscopic images were compared.
RESULTS: Representative images showed that OCT image provides the insight into sealant material. It was possible to clearly identify the internal structure of sealant and the subjacent enamel. Sealant and enamel are very well distinguished, and failures at the interior and at surface are well detected. SIGNIFICANCE: OCT could generate images of the features of fissures, bubbles and failures in the adaptation of sealants, opening up possibilities in the future to monitoring sealant application and retention in short and long term.
Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21159372     DOI: 10.1016/j.dental.2010.11.010

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  8 in total

1.  Failure analysis of adhesive restorations with SEM and OCT: from marginal gaps to restoration loss.

Authors:  Tissiana Bortolotto; Jose Bahillo; Olivier Richoz; Farhad Hafezi; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2015-02-01       Impact factor: 3.573

2.  Clinical cross-polarization optical coherence tomography assessment of subsurface enamel below dental resin composite restorations.

Authors:  Patricia Lenton; Joel Rudney; Alex Fok; Robert S Jones
Journal:  J Med Imaging (Bellingham)       Date:  2014-05-07

3.  Indirect evaluation of pit and fissure sealants: A 3D-based method validation.

Authors:  Kelly Moreira; Kamila Kantovitz; Tamires Bueno; Maria-Angélica Agulhari; Fabio Rizzante; Juliana Aguiar; Fernanda Pascon; Vanessa Arias; Ana-Flávia Borges; Regina-Maria Rontani
Journal:  J Clin Exp Dent       Date:  2020-09-01

4.  Marginal and internal analysis of preheated dental fissure-sealing materials using optical coherence tomography.

Authors:  Boniek Castillo Dutra Borges; Isauremi Vieira de Assunção; Célia Avani de Aquino; Gabriela Queiroz de Melo Monteiro; Anderson Stevens Leonidas Gomes
Journal:  Int Dent J       Date:  2015-10-18       Impact factor: 2.607

Review 5.  Dental optical coherence tomography.

Authors:  Yao-Sheng Hsieh; Yi-Ching Ho; Shyh-Yuan Lee; Ching-Cheng Chuang; Jui-che Tsai; Kun-Feng Lin; Chia-Wei Sun
Journal:  Sensors (Basel)       Date:  2013-07-12       Impact factor: 3.576

6.  Noninvasive Quantitative Evaluation of the Dentin Layer during Dental Procedures Using Optical Coherence Tomography.

Authors:  Cosmin Sinescu; Meda Lavinia Negrutiu; Adrian Bradu; Virgil-Florin Duma; Adrian Gh Podoleanu
Journal:  Comput Math Methods Med       Date:  2015-05-19       Impact factor: 2.238

7.  Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial.

Authors:  Camillo Anauate-Netto; Laurindo Borelli; Ricardo Amore; Vinicius DI Hipólito; Paulo Henrique Perlatti D'Alpino
Journal:  J Appl Oral Sci       Date:  2017 Jul-Aug       Impact factor: 2.698

Review 8.  The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review.

Authors:  Monika Machoy; Julia Seeliger; Liliana Szyszka-Sommerfeld; Robert Koprowski; Tomasz Gedrange; Krzysztof Woźniak
Journal:  J Healthc Eng       Date:  2017-07-16       Impact factor: 2.682

  8 in total