Literature DB >> 21158587

Comparison of peripapillary retinal nerve fiber layer thickness measured by spectral vs. time domain optical coherence tomography.

Samin Hong1, Gong Je Seong, Sung Soo Kim, Sung Yong Kang, Chan Yun Kim.   

Abstract

PURPOSE: To compare the peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral and time domain optical coherence tomography (OCT). PATIENTS AND METHODS: One hundred and eighty-eight subjects (normal tension glaucoma, n = 80; primary open angle glaucoma, n = 49; healthy controls, n = 59) were included in this study. Peripapillary RNFL thickness was measured by an Optic Disc Cube 200 × 200 scan of the spectral domain Cirrus HD OCT and by a Fast RNFL scan of the time domain Stratus OCT. They were compared using linear regression (R(2)), Bland-Altman plots, weighted Kappa (K(w)) coefficients, and areas under the receiver operating characteristic curve (AROC).
RESULTS: Except for the inferior quadrant, RNFL thickness measurements by Cirrus HD OCT were thinner than Stratus OCT (all p < 0.001); for the inferior quadrant, this tendency was vice versa (p  =  0.043). Average RNFL thicknesses of the two OCTs showed a good correlation (R(2), 0.852) but not excellent agreement (mean of difference, 4.0 μm; +1.96 SD, 10.7 μm; -1.96 SD, -18.6 μm). Regarding the probability codes, only the average RNFL thickness had almost perfect agreement (K(w), 0.983). In addition, Cirrus HD OCT had the largest AROC for the superior quadrant (0.795), but Stratus OCT had the largest AROC for average RNFL thickness (0.764) (p  =  0.281).
CONCLUSIONS: Except for the inferior quadrant, the average and quadrants RNFL thickness measured by the Cirrus HD OCT were thinner than the Stratus OCT. Regarding discriminating power for glaucoma detection, the Cirrus HD OCT was better than the Stratus OCT for the superior and inferior quadrant RNFL thicknesses but not for the average RNFL thickness.

Entities:  

Mesh:

Year:  2010        PMID: 21158587     DOI: 10.3109/02713683.2010.533807

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  5 in total

1.  Diagnostic performance and reproducibility of circumpapillary retinal nerve fiber layer thickness measurement in 10-degree sectors in early stage glaucoma.

Authors:  Hiroyo Hirasawa; Chihiro Mayama; Atsuo Tomidokoro; Makoto Araie; Aiko Iwase; Kazuhisa Sugiyama; Shoji Kishi; Naoyuki Maeda; Nagahisa Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2014-12-19       Impact factor: 2.447

Review 2.  Parameters of ocular fundus on spectral-domain optical coherence tomography for glaucoma diagnosis.

Authors:  Yu-Lin Tao; Li-Ming Tao; Zheng-Xuan Jiang; He-Ting Liu; Kun Liang; Mo-Han Li; Xuan-Sheng Zhu; Yan-Lin Ren; Bing-Jie Cui
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

3.  A formula to predict spectral domain optical coherence tomography (OCT) retinal nerve fiber layer measurements based on time domain OCT measurements.

Authors:  Kang Hoon Lee; Min Gu Kang; Hyunsun Lim; Chan Yun Kim; Na Rae Kim
Journal:  Korean J Ophthalmol       Date:  2012-09-24

4.  Evaluation of Agreement between HRT III and iVue OCT in Glaucoma and Ocular Hypertension Patients.

Authors:  A Perdicchi; M Iester; D Iacovello; A Cutini; M Balestrieri; M G Mutolo; A Ferreras; M T Contestabile; S M Recupero
Journal:  J Ophthalmol       Date:  2015-12-15       Impact factor: 1.909

5.  Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis.

Authors:  Vinay Kansal; James J Armstrong; Robert Pintwala; Cindy Hutnik
Journal:  PLoS One       Date:  2018-01-04       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.