Literature DB >> 21156363

Noninvasive thermometry assisted by a dual-function ultrasound transducer for mild hyperthermia.

Chun-Yen Lai1, Dustin E Kruse, Charles F Caskey, Douglas N Stephens, Patrick L Sutcliffe, Katherine W Ferrara.   

Abstract

Mild hyperthermia is increasingly important for the activation of temperature-sensitive drug delivery vehicles. Noninvasive ultrasound thermometry based on a 2-D speckle tracking algorithm was examined in this study. Here, a commercial ultrasound scanner, a customized co-linear array transducer, and a controlling PC system were used to generate mild hyperthermia. Because the co-linear array transducer is capable of both therapy and imaging at widely separated frequencies, RF image frames were acquired during therapeutic insonation and then exported for off-line analysis. For in vivo studies in a mouse model, before temperature estimation, motion correction was applied between a reference RF frame and subsequent RF frames. Both in vitro and in vivo experiments were examined; in the in vitro and in vivo studies, the average temperature error had a standard deviation of 0.7°C and 0.8°C, respectively. The application of motion correction improved the accuracy of temperature estimation, where the error range was 1.9 to 4.5°C without correction compared with 1.1 to 1.0°C following correction. This study demonstrates the feasibility of combining therapy and monitoring using a commercial system. In the future, real-time temperature estimation will be incorporated into this system.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21156363      PMCID: PMC3018687          DOI: 10.1109/TUFFC.2010.1741

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  30 in total

Review 1.  Magnetic resonance temperature imaging for guidance of thermotherapy.

Authors:  B Quesson; J A de Zwart; C T Moonen
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

2.  Inducing and imaging thermal strain using a single ultrasound linear array.

Authors:  Sheng-Wen Huang; Kang Kim; Russell S Witte; Ragnar Olafsson; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-09       Impact factor: 2.725

3.  Two-dimensional temperature estimation using diagnostic ultrasound.

Authors:  C Simon; P Vanbaren; E S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

4.  Driving delivery vehicles with ultrasound.

Authors:  Katherine W Ferrara
Journal:  Adv Drug Deliv Rev       Date:  2008-03-30       Impact factor: 15.470

5.  Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound.

Authors:  R Seip; E S Ebbini
Journal:  IEEE Trans Biomed Eng       Date:  1995-08       Impact factor: 4.538

6.  Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study.

Authors:  R Maass-Moreno; C A Damianou; N T Sanghvi
Journal:  J Acoust Soc Am       Date:  1996-10       Impact factor: 1.840

7.  Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical model.

Authors:  R Maass-Moreno; C A Damianou
Journal:  J Acoust Soc Am       Date:  1996-10       Impact factor: 1.840

Review 8.  Implications of increased tumor blood flow and oxygenation caused by mild temperature hyperthermia in tumor treatment.

Authors:  C W Song; H J Park; C K Lee; R Griffin
Journal:  Int J Hyperthermia       Date:  2005-12       Impact factor: 3.914

9.  Pathological changes in human malignant carcinoma treated with high-intensity focused ultrasound.

Authors:  F Wu; W Z Chen; J Bai; J Z Zou; Z L Wang; H Zhu; Z B Wang
Journal:  Ultrasound Med Biol       Date:  2001-08       Impact factor: 2.998

10.  Pulsed high-intensity focused ultrasound enhances uptake of radiolabeled monoclonal antibody to human epidermoid tumor in nude mice.

Authors:  Alfia Khaibullina; Beom-Su Jang; Haihao Sun; Nhat Le; Sarah Yu; Victor Frenkel; Jorge A Carrasquillo; Ira Pastan; King C P Li; Chang H Paik
Journal:  J Nucl Med       Date:  2008-01-16       Impact factor: 10.057

View more
  19 in total

1.  Development of a spherically focused phased array transducer for ultrasonic image-guided hyperthermia.

Authors:  Jingfei Liu; Josquin Foiret; Douglas N Stephens; Olivier Le Baron; Katherine W Ferrara
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

2.  Thermal strain imaging: a review.

Authors:  Chi Hyung Seo; Yan Shi; Sheng-Wen Huang; Kang Kim; Matthew O'Donnell
Journal:  Interface Focus       Date:  2011-05-23       Impact factor: 3.906

3.  Registration of human skull computed tomography data to an ultrasound treatment space using a sparse high frequency ultrasound hemispherical array.

Authors:  Meaghan A O'Reilly; Ryan M Jones; Gabriel Birman; Kullervo Hynynen
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

Review 4.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

5.  Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.

Authors:  Brooks D Lindsey; Jinwook Kim; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-05-08       Impact factor: 2.725

6.  High contrast power Doppler imaging in side-viewing intravascular ultrasound imaging via angular compounding.

Authors:  Graham C Collins; Bowen Jing; Brooks D Lindsey
Journal:  Ultrasonics       Date:  2020-06-02       Impact factor: 2.890

7.  Convergence of nanotechnology with radiation therapy-insights and implications for clinical translation.

Authors:  Dev Kumar Chatterjee; Tatiana Wolfe; Jihyoun Lee; Aaron P Brown; Pankaj Kumar Singh; Shanta Raj Bhattarai; Parmeswaran Diagaradjane; Sunil Krishnan
Journal:  Transl Cancer Res       Date:  2013-08-23       Impact factor: 1.241

8.  Detecting hepatic steatosis using ultrasound-induced thermal strain imaging: an ex vivo animal study.

Authors:  Ahmed M Mahmoud; Xuan Ding; Debaditya Dutta; Vijay P Singh; Kang Kim
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

9.  Creation and characterization of an ultrasound and CT phantom for noninvasive ultrasound thermometry calibration.

Authors:  Dustin E Kruse; Katherine W Ferrara; Charles F Caskey
Journal:  IEEE Trans Biomed Eng       Date:  2013-09-19       Impact factor: 4.538

10.  Improved Estimation of Ultrasound Thermal Strain Using Pulse Inversion Harmonic Imaging.

Authors:  Xuan Ding; Man M Nguyen; Isaac B James; Kacey G Marra; J Peter Rubin; Steven A Leers; Kang Kim
Journal:  Ultrasound Med Biol       Date:  2016-03-02       Impact factor: 2.998

View more