Literature DB >> 21147418

Ultrasonography of longus colli muscle: A reliability study on healthy subjects and patients with chronic neck pain.

Khodabakhsh Javanshir1, Mohammad Ali Mohseni-Bandpei, Asghar Rezasoltani, Mohsen Amiri, Mehdi Rahgozar.   

Abstract

In this study, the reliability of the longus colli muscle (LCM) size was assessed in a relaxed state by a real time ultrasonography (US) device in a group of healthy subjects and a group of patients with chronic neck pain. Fifteen healthy subjects (19-41 years old) and 10 patients with chronic neck pain (27-44 years old) were recruited for the purpose of this study. LCM size was measured at the level of thyroid cartilage. Two images were taken on the same day with an hour interval to assess the within day reliability and the third image was taken 1 week later to determine between days reliability. Cross sectional area (CSA), anterior posterior dimension (APD), and lateral dimension (LD) were measured each time. The shape ratio was calculated as LD/APD. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were computed for data analysis. The ICC of left and right CSA for within day and between days reliability in healthy subjects were (0.90, 0.93) and (0.85, 0.82), respectively. The ICC of left and right CSA for within day and between days reliability in patients with neck pain were (0.86, 0.82) and (0.76, 0.81), respectively. The results indicated that US could be used as a reliable tool to measure the LCM dimensions in healthy subjects and patients with chronic neck pain.
Copyright © 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 21147418     DOI: 10.1016/j.jbmt.2009.07.005

Source DB:  PubMed          Journal:  J Bodyw Mov Ther        ISSN: 1360-8592


  12 in total

1.  Ultrasonography for the assessment of the upper trapezius properties in healthy females: a reliability study.

Authors:  Hakimeh Adigozali; Azadeh Shadmehr; Esmail Ebrahimi; Asghar Rezasoltani; Farrokh Naderi
Journal:  Muscles Ligaments Tendons J       Date:  2016-05-19

2.  Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study.

Authors:  Leila Rahnama; Asghar Rezasoltani; Minoo Khalkhali-Zavieh; Behnam Rahnama; Farhang Noori-Kochi
Journal:  Braz J Phys Ther       Date:  2015-09-01       Impact factor: 3.377

3.  The effect of cocontraction of the masticatory muscles during neck stabilization exercises on thickness of the neck flexors.

Authors:  Hyun-Ju Moon; Bong-Oh Goo; Sung-Hak Cho
Journal:  J Phys Ther Sci       Date:  2015-03-31

4.  The ratio of change in muscle thickness between superficial and deep cervical flexor muscles during the craniocervical flexion test and a suggestion regarding clinical treatment of patients with musculoskeletal neck pain.

Authors:  Miran Goo; Seong-Gil Kim; Deokhoon Jun
Journal:  J Phys Ther Sci       Date:  2015-08-21

5.  Changes in the thickness of the cervical flexor depending on the contraction level of the masticatory muscle during deep cervical flexor training.

Authors:  Hyun-Ju Moon; Bong-Oh Goo; Hae-Yeon Kwon
Journal:  J Phys Ther Sci       Date:  2015-11-30

6.  Reliability of ultrasonography measurement for the longus colli according to inward probe pressure.

Authors:  Byoung-Lock Jeong; Sung-Min Ha; In-Cheol Jeon; Ki-Hoon Hong
Journal:  J Phys Ther Sci       Date:  2015-11-30

7.  Musculoskeletal diagnostic ultrasound imaging for thickness measurement of four principal muscles of the cervical spine -a reliability and agreement study.

Authors:  Cecilie Krage Øverås; Birgitte Lawaetz Myhrvold; Gro Røsok; Eli Magnesen
Journal:  Chiropr Man Therap       Date:  2017-01-04

8.  Comparison of cervical muscle thickness between asymptomatic women with and without forward head posture.

Authors:  Fateme Bokaee; Asghar Rezasoltani; Farideh D Manshadi; Sedigheh S Naimi; Alireza A Baghban; Hadi Azimi
Journal:  Braz J Phys Ther       Date:  2017-04-19       Impact factor: 3.377

9.  Surgical Anatomy of the Longus Colli Muscle and Uncinate Process in the Cervical Spine.

Authors:  Moon Soo Park; Seong Hwan Moon; Tae Hwan Kim; Jae Keun Oh; Hyung Joon Kim; Kun Tae Park; K Daniel Riew
Journal:  Yonsei Med J       Date:  2016-07       Impact factor: 2.759

10.  The effects of eye coordination during deep cervical flexor training on the thickness of the cervical flexors.

Authors:  Hyun-Ju Moon; Bong-Oh Goo; Hae-Yeon Kwon; Jun-Hyeok Jang
Journal:  J Phys Ther Sci       Date:  2015-12-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.