Literature DB >> 21147298

Potentials and limitations of low-concentration contrast medium (150 mg iodine/ml) in CT pulmonary angiography.

M R Radon1, M J Kaduthodil, J Jagdish, S Matthews, C Hill, M J Bull, S K Morcos.   

Abstract

AIM: To assess the feasibility of producing diagnostic multidetector computed tomography (MDCT) pulmonary angiography with low iodine concentration contrast media (150 mg iodine/ml) in patients with suspected acute pulmonary embolism.
MATERIALS AND METHODS: Ninety-five randomized patients underwent MDCT (64 row) pulmonary angiography with 100ml iopromide either at low concentration (LC) of 150 mg iodine/ml (n=45) or high concentration (HC) of 300 mg iodine/ml (n=50), delivered at the rate of 5 ml/s via a power injector. Two experienced radiologists, blinded to the concentration used, subjectively assessed the diagnostic quality and confidence using a four-point scale [1=poor (not diagnostic), 2=satisfactory, 3=good, 4=excellent]. Attenuation values (in HU) were measured in the main proximal branches of the pulmonary arteries.
RESULTS: The median diagnostic quality score for both observers was 3.5 (interquartile range 3-4) in the HC group and 2.5 (interquartile range 1.5-3) in the LC group (p<0.01). The median diagnostic confidence score for both observers was 4 (interquartile range 3-4) in the HC group and 3 (interquartile range 1.5-4) in the LC group (p<0.01). Both observers rated examinations as diagnostic in 69% of cases in the LC group, compared with 96% of cases in the HC group. Good interobserver agreement was found in both groups (K value 0.72 in the LC group and 0.73 in the HC). Obesity, poor scan timing, and dilution by venous return of non-opacified blood were the main reasons for a reduction in diagnostic quality of examinations in the LC group.
CONCLUSION: Despite a 50% reduction of contrast medium dose in comparison to the standard technique, 150 mg iodine/ml can produce diagnostic MDCT pulmonary angiogram studies in the absence of obesity or high cardiac output and hyper-dynamic pulmonary circulation. Reducing the dose of contrast media would minimize the risk of contrast nephropathy in patients at risk of this complication, particularly those suffering from congestive heart failure in whom intravenous hydration is contraindicated.
Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21147298     DOI: 10.1016/j.crad.2010.05.011

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  1 in total

1.  CT angiography for pulmonary embolism in the emergency department: investigation of a protocol by 20 ml of high-concentration contrast medium.

Authors:  Mario Silva; Gianluca Milanese; Rocco Cobelli; Carmelinda Manna; Edoardo Rasciti; Sara Poggesi; Nicola Sverzellati
Journal:  Radiol Med       Date:  2019-10-28       Impact factor: 3.469

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.