PURPOSE: To examine and compare in an ex vivo study different nitinol stent designs intended for the superficial femoral artery (SFA) with regard to the appearance of fracture. METHODS: Seven different 8-×40-mm nitinol stents were evaluated (Misago, Absolute, Smart, Luminexx, Sentinol, Lifestent NT, and Sinus-Superflex). Finite element analysis (FEA) was used for digitalized stent design comparison; the strain during stent movement was calculated for bending, compression, and torsion. Additional mechanical fatigue tests for bending (70°), compression (40%), and torsion (twisted counterclockwise by 180°) were performed up to 650,000 cycles or until a fracture was observed. RESULTS: The FEA bending test showed that only the Misago, LifeStent, and Absolute stents presented no zones of high strain; in the torsion test, the Smart stent also had no zones of high strain. Macroscopic evaluation after mechanical bending indicated that the LifeStent performed the best (no stent fracture after 650,000 cycles). Misago and Absolute stents showed fractures at 536,000 cycles and 456,667 cycles, respectively (range 320,000-650,000 cycles). After compression and torsion testing, Misago showed no stent fracture after 650,000 cycles. The worst performing stent was Luminexx during all test cycles. CONCLUSION: The 7 SFA stents showed differences in the incidence of high strain zones, which indicates a potential for stent fracture, as demonstrated by the mechanical fatigue tests. Differences in stent design might play a major role in the appearance of stent strut fracture related to restenosis and reocclusion.
PURPOSE: To examine and compare in an ex vivo study different nitinol stent designs intended for the superficial femoral artery (SFA) with regard to the appearance of fracture. METHODS: Seven different 8-×40-mm nitinol stents were evaluated (Misago, Absolute, Smart, Luminexx, Sentinol, Lifestent NT, and Sinus-Superflex). Finite element analysis (FEA) was used for digitalized stent design comparison; the strain during stent movement was calculated for bending, compression, and torsion. Additional mechanical fatigue tests for bending (70°), compression (40%), and torsion (twisted counterclockwise by 180°) were performed up to 650,000 cycles or until a fracture was observed. RESULTS: The FEA bending test showed that only the Misago, LifeStent, and Absolute stents presented no zones of high strain; in the torsion test, the Smart stent also had no zones of high strain. Macroscopic evaluation after mechanical bending indicated that the LifeStent performed the best (no stent fracture after 650,000 cycles). Misago and Absolute stents showed fractures at 536,000 cycles and 456,667 cycles, respectively (range 320,000-650,000 cycles). After compression and torsion testing, Misago showed no stent fracture after 650,000 cycles. The worst performing stent was Luminexx during all test cycles. CONCLUSION: The 7 SFA stents showed differences in the incidence of high strain zones, which indicates a potential for stent fracture, as demonstrated by the mechanical fatigue tests. Differences in stent design might play a major role in the appearance of stent strut fracture related to restenosis and reocclusion.
Authors: Karla Maria Treitl; Benedikt Woerner; Regina Schinner; Michael Czihal; Susan Notohamiprodjo; Ulrich Hoffmann; Marcus Treitl Journal: Eur Radiol Date: 2017-02-06 Impact factor: 5.315
Authors: Jennifer M Bastijanic; Jordan Etscheidt; Mallika Sattiraju; Craig Bonsignore; George Kopchok; Rodney White; Timur P Sarac Journal: J Endovasc Ther Date: 2014-10 Impact factor: 3.487
Authors: Kaspars Maleckis; Eric Anttila; Paul Aylward; William Poulson; Anastasia Desyatova; Jason MacTaggart; Alexey Kamenskiy Journal: Ann Biomed Eng Date: 2018-02-22 Impact factor: 3.934
Authors: Sang Ho Park; Seung Woon Rha; Cheol Ung Choi; Eung Ju Kim; Dong Joo Oh; Yun Hyeong Cho; Woong Gil Choi; Seung Jin Lee; Yong Hoon Kim; Seung Hyuk Choi; Won Ho Kim; Ki Chang Kim; Jang Hyun Cho; Joo Han Kim; Sang Min Kim; Jang Ho Bae; Jung Min Bong; Won Yu Kang; Ju Yeol Baek; Jae Bin Seo; Woo Young Chung; Mahn Won Park; Sung Ho Her; Jon Suh; Min Woong Kim; Yeo Joo Kim; Hwan Jun Choi; Jae Wan Soh Journal: Trials Date: 2014-09-10 Impact factor: 2.279