Literature DB >> 21136130

Intraindividual comparison of gadolinium- and iodine-enhanced 64-slice multidetector CT pulmonary angiography for the detection of pulmonary embolism in a porcine model.

Frank Oliver Gerhard Henes1, Michael Groth, Philipp G C Begemann, Gerhard Adam, Marc Regier.   

Abstract

This study is an evaluation of the diagnostic accuracy of gadolinium-enhanced computed tomography pulmonary angiography (CTPA) for the detection of pulmonary embolism (PE) in comparison with iodine-enhanced CTPA. PE was induced in five anesthetized pigs by administration of blood clots through an 11-F catheter inside the jugular vein. Animals underwent CTPA in breathhold with i.v. bolus injection of 50 ml gadopentetate dimeglumine (0.4 mmol/kg, 4 ml/s). Subsequently, CTPA was performed using the same imaging parameters but under administration of 70 ml nonionic iodinated contrast material (400 mg/ml, 4 ml/s). All images were reconstructed with 1 mm slice thickness. A consensus readout of the iodium-enhanced CTPAs by both radiologists served as reference standard. Gadolinium-enhanced CTPAs were evaluated independently by two experienced radiologists, and differences in detection rate between both contrast agents were assessed on a per embolus basis using the Wilcoxon signed-rank test. Interobserver agreement was determined by calculation of қ values. PE was diagnosed independently by both readers in all five pigs by the use of gadolinium-enhanced CTPA. Out of 60 pulmonary emboli detected in the iodine-enhanced scans, 47 (78.3%; reader 1) and 44 (62.8%; reader 2) emboli were detected by the use of gadolinium. All 13 (100%) emboli in lobar arteries (by both readers) and 26 (reader 1) and 25 (reader 2) out of 27 emboli (96.3% and 92.6%) in segmental arteries were detected by the use of the gadolinium-enhanced CTPA. In subsegmental arteries, only 8 (40%; reader 1) and 6 (30%; reader 2) out of 20 emboli were detected by the gadolinium-enhanced CTPA. By comparing both scans on a per vessel basis (Wilcoxon test), Gd-enhanced CTPA was significantly inferior in emboli detection on subsegmental level (P < 0.0001). The interobserver agreement was excellent on lobar and segmental level (қ = 1.0 and 0.93, respectively), whereas readers only reached moderate agreement for PE evaluation on subsegmental level (қ = 0.56). Compared to conventional CTPA with iodinated contrast media, gadolinium-based contrast agents achieve an equivalent diagnostic accuracy in detection of PE down to segmental level. Gadolinium-enhanced CTPA may be considered as an alternative for the diagnostic workup of acute pulmonary embolism in patients with contraindications to iodinated contrast agents.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21136130     DOI: 10.1007/s10140-010-0926-3

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  37 in total

1.  Gadolinium-DTPA as X-ray contrast medium in clinical studies.

Authors:  T Albrecht; P Dawson
Journal:  Br J Radiol       Date:  2000-08       Impact factor: 3.039

2.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

3.  Gd-DTPA as an alternative contrast agent in conventional and interventional radiology.

Authors:  T Vehmas; A T Markkola
Journal:  Acta Radiol       Date:  1998-05       Impact factor: 1.990

4.  Safety and effectiveness of gadolinium-enhanced multi-detector row spiral CT angiography of the chest: preliminary results in 37 patients with contraindications to iodinated contrast agents.

Authors:  Martine Remy-Jardin; Philippe Dequiedt; Olivier Ertzbischoff; Isabelle Tillie-Leblond; John Bruzzi; Alain Duhamel; Jacques Remy
Journal:  Radiology       Date:  2005-04-21       Impact factor: 11.105

Review 5.  Helical CT for the evaluation of acute pulmonary embolism.

Authors:  Smita Patel; Ella A Kazerooni
Journal:  AJR Am J Roentgenol       Date:  2005-07       Impact factor: 3.959

6.  Diagnosis of pulmonary embolism: comparison of CT angiography and MR angiography in canines.

Authors:  D R Hurst; E A Kazerooni; D Stafford-Johnson; D M Williams; J F Platt; P N Cascade; M R Prince
Journal:  J Vasc Interv Radiol       Date:  1999-03       Impact factor: 3.464

7.  Multidetector-row computed tomography in suspected pulmonary embolism.

Authors:  Arnaud Perrier; Pierre-Marie Roy; Olivier Sanchez; Grégoire Le Gal; Guy Meyer; Anne-Laurence Gourdier; Alain Furber; Marie-Pierre Revel; Nigel Howarth; Alain Davido; Henri Bounameaux
Journal:  N Engl J Med       Date:  2005-04-28       Impact factor: 91.245

8.  Suspected pulmonary embolism: prevalence and anatomic distribution in 487 consecutive patients. Advances in New Technologies Evaluating the Localisation of Pulmonary Embolism (ANTELOPE) Group.

Authors:  W de Monyé; M J van Strijen; M V Huisman; G J Kieft; P M Pattynama
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

9.  Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT.

Authors:  E E Coche; F D Hammer; P P Goffette
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

10.  Comparison of contrast-enhanced ct angiography and gadolinium-enhanced MR angiography in the detection of subsegmental-sized pulmonary embolism. An experimental study in a pig model.

Authors:  J B Seo; J-G Im; J M Goo; M J Chung; W K Moon; K H Lee; I-O Kim
Journal:  Acta Radiol       Date:  2003-07       Impact factor: 1.701

View more
  2 in total

1.  Qualitative indices and enhancement rate of CT pulmonary angiography in patients with suspected pulmonary embolism: Comparison between test bolus and bolus-tracking methods.

Authors:  Maryam Moradi; Babak Khalili
Journal:  Adv Biomed Res       Date:  2016-06-20

2.  Perfusion-ventilation CT via three-material differentiation in dual-layer CT: a feasibility study.

Authors:  Andreas P Sauter; Johannes Hammel; Sebastian Ehn; Klaus Achterhold; Felix K Kopp; Melanie A Kimm; Kai Mei; Alexis Laugerette; Franz Pfeiffer; Ernst J Rummeny; Daniela Pfeiffer; Peter B Noël
Journal:  Sci Rep       Date:  2019-04-09       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.