Literature DB >> 21135488

Diagnosis, therapy monitoring and follow up of renal artery pseudoaneurysm with contrast-enhanced ultrasound in three cases.

A Helck1, R T Hoffmann, W H Sommer, M Notohamiprodjo, H Albyaa, M Reiser, D A Clevert.   

Abstract

PURPOSE: We describe the presentation of renal artery pseudoaneurysm (RAP) in different imaging modalities (CT, DSA, standard US, contrast enhanced ultrasound (CEUS)). In particular the benefit of CEUS with regards to therapy monitoring and follow up care shall be highlighted.
MATERIALS AND METHODS: Three patients with renal artery pseudoaneurysm after renal surgery were investigated with CT and/or US (grey-scaled US, color duplex US, CEUS), respectively. The therapy (angiography-coiling) was monitored using contrast-enhanced ultrasound.
RESULTS: Accurate diagnosis of RAP in our study was yielded using color duplex US and CEUS. CEUS was very practical for therapy monitoring of coil embolization with the potential of shortening the invasive DSA. Thus, CEUS has potential of radiation dose reduction and the potential of saving coils with the result of cost reduction.
CONCLUSION: CEUS is an appropriate approach for monitoring coil embolization of RAP.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21135488     DOI: 10.3233/CH-2010-1339

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  5 in total

1.  [Interventional sonography of the liver and kidneys].

Authors:  D-A Clevert; E M Jung
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

2.  Role of color Doppler ultrasound in the early diagnosis of a major complication after percutaneous renal biopsy: two case reports.

Authors:  Dolores Ferrara; Francesco Esposito; Roberta Blasio; Rosanna Mamone; Rosa Severino; Marco Di Serafino; Carmine Pecoraro; Massimo Zeccolini
Journal:  J Ultrasound       Date:  2018-10-11

3.  Giant peripancreatic artery aneurysm with emphasis on contrast-enhanced ultrasound: report of two cases.

Authors:  Baoxian Liu; Luyao Zhou; Ming Liu; Xiaoyan Xie
Journal:  J Med Ultrason (2001)       Date:  2014-09-06       Impact factor: 1.314

4.  Incidental renal artery pseudoaneurysm after percutaneous native renal biopsy.

Authors:  Hae Kyung Yang; Eun Sil Koh; Seok Joon Shin; Sungjin Chung
Journal:  BMJ Case Rep       Date:  2013-02-25

5.  High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old.

Authors:  Uygar Teomete; Rubee Anne Gugol; Holly Neville; Ozgur Dandin; Ming-Lon Young
Journal:  Case Rep Vasc Med       Date:  2016-01-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.