Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures.

Charalampos G Zalavras1, Michael T Vercillo, Bong-Jae Jun, Karimdad Otarodifard, John M Itamura, Thay Q Lee.   

Abstract

BACKGROUND: Orthogonal and parallel plate constructs are used for fixation of intra-articular distal humerus fractures but optimal plate configuration remains controversial. The purpose of this study was to compare the biomechanical properties of orthogonal versus parallel plate constructs in a cadaver distal humerus fracture model.
MATERIAL AND METHODS: An intra-articular distal humerus fracture with a metaphyseal defect was created in 14 matched pairs of cadaver elbows. Paired specimens were fixed with either orthogonal or parallel plates from a single elbow plating system using nonlocking screws. Using a novel testing protocol, loading was applied to the forearm and was transmitted to the distal humerus through intact collateral ligaments, olecranon, and radial head. Seven matched pairs were tested under varus loading and seven under axial/sagittal loading. Each specimen underwent cyclic loading first, followed by loading to failure.
RESULTS: Parallel plate constructs had significantly higher stiffness than orthogonal ones during cyclic varus loading (P = .002). Screw loosening occurred in all posterior plates of orthogonal constructs but in no plates of parallel constructs (P = .001). Parallel constructs had significantly higher ultimate torque in varus loading to failure (20.7 vs 15.9 Nm, P = .008), and higher ultimate load in axial/sagittal loading to failure (1287.8 vs 800.0 N, P = .03). DISCUSSION: Parallel plating of intra-articular distal humerus fractures with a metaphyseal defect demonstrates superior biomechanical properties compared to orthogonal plating, and may be preferable for fixation of these fractures.
Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21134662     DOI: 10.1016/j.jse.2010.08.005

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  19 in total

1.  Biomechanical study of different plate configurations for distal humerus osteosynthesis.

Authors:  M Bogataj; F Kosel; R Norris; M Krkovic; M Brojan
Journal:  Med Biol Eng Comput       Date:  2015-02-08       Impact factor: 2.602

2.  Arterial supply of the distal humerus.

Authors:  Kilian Wegmann; K J Burkhart; T C Koslowsky; J Koebke; W F Neiss; L P Müller
Journal:  Surg Radiol Anat       Date:  2013-12-04       Impact factor: 1.246

3.  Biomechanical evaluation of metacarpal fracture fixation: application of a 90° internal fixation model.

Authors:  Andrew J Watt; Randal P Ching; Jerry I Huang
Journal:  Hand (N Y)       Date:  2015-03

4.  Biomechanical comparison of anatomical plating systems for comminuted distal humeral fractures.

Authors:  Patrick A Varady; Christian von Rüden; Markus Greinwald; Sven Hungerer; Robert Pätzold; Peter Augat
Journal:  Int Orthop       Date:  2017-03-27       Impact factor: 3.075

Review 5.  Intra-articular fractures of the distal humerus-a review of the current practice.

Authors:  Charalampos G Zalavras; Efthymios Papasoulis
Journal:  Int Orthop       Date:  2018-02-05       Impact factor: 3.075

6.  Arthroplasty compared to internal fixation by locking plate osteosynthesis in comminuted fractures of the distal humerus.

Authors:  Alexander Ellwein; Helmut Lill; Christine Voigt; Pauline Wirtz; Gunnar Jensen; Jan Christoph Katthagen
Journal:  Int Orthop       Date:  2014-12-23       Impact factor: 3.075

7.  Parallel versus orthogonal plate osteosynthesis of adult distal humerus fractures: a meta-analysis of biomechanical studies.

Authors:  Chien-An Shih; Wei-Ren Su; Wei-Chin Lin; Tai-Wei Tai
Journal:  Int Orthop       Date:  2018-04-20       Impact factor: 3.075

8.  A comparison between orthogonal and parallel plating methods for distal humerus fractures: a prospective randomized trial.

Authors:  Sang Ki Lee; Kap Jung Kim; Kyung Hoon Park; Won Sik Choy
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-08-07

9.  Modified Tension Band Wiring in Adult Distal Humeral Fracture Types A2 and C1.

Authors:  Saeed Kokly; Alessandro Castagna; Mohamadreza Mohamadreza
Journal:  Arch Bone Jt Surg       Date:  2019-07

10.  Does posterior configuration have similar strength as parallel configuration for treating comminuted distal humerus fractures? A cadaveric biomechanical study.

Authors:  Chien-An Shih; Fa-Chuan Kuan; Kai-Lan Hsu; Chih-Kai Hong; Cheng-Li Lin; Ming-Long Yeh; Wei-Ren Su
Journal:  BMC Musculoskelet Disord       Date:  2021-05-14       Impact factor: 2.362