Literature DB >> 24306043

Arterial supply of the distal humerus.

Kilian Wegmann1, K J Burkhart, T C Koslowsky, J Koebke, W F Neiss, L P Müller.   

Abstract

PURPOSE: Distal humeral fractures are rare, but severe injuries, the treatment of which is often accompanied by serious complications and its outcome strongly depends on the quality of surgical therapy. Non-union is a common entity, compromising clinical results and requiring revision surgery. Osteonecrosis is an underestimated etiologic factor in the development of non-union. The present study aims to display the distribution patterns of the arterial vessels at the distal humerus, to correlate the displayed vessels with local nutrient foramina and to disclose an endangerment of these structures by common osteosynthetic implants.
METHODS: Eight plastinated fresh frozen upper extremities were digitally analyzed regarding the vascular density of the cancellous bone, by calculating the ratio of area comprised by arterial vessels and the area comprised by cancellous bone on sagittal cuts of the distal humerus. Possible differences in the vascular density of the medial epicondylar region, the lateral epicondylar region and a watershed area between the epicondyles and distal to the supracondylar region were investigated. On the basis of 200 macerated humeri, the distribution pattern of cortical nutrient foramina and their anatomic relation to properly applied common distal humerus plates were documented.
RESULTS: The data show a significantly higher density of vessels per cancellous bone in the epicondylar regions than in the watershed region (p < 0.000, median 0.148 vs. 0.103). The analysis of the nutrient foramina showed distinct distribution patterns with a single foramen over the medial epicondyle (55 specimens, 27.5 %) and an area of several foramina at the posterior part of the lateral epicondyle (200 of the specimens, 100 %). In almost every specimen, the application of the osteosynthetic implants led to an overlay over the investigated nutrient foramina. DISCUSSION: Osteonecrosis and non-union are severe complications in the surgical treatment of distal humeral fractures. The biology of the bone, especially the blood supply, has to be respected as much as possible during open procedures, to optimize bony healing. This has to be considered when performing periosteal stripping or applying osteosynthetic plates over the postero-lateral and medial epicondyle. The watershed area of the distal humerus has to be considered as being prone to minor arterial blood supply and thereby non-union is possible, if the arterial vessels coming from the epicondyles are destroyed.

Entities:  

Mesh:

Year:  2013        PMID: 24306043     DOI: 10.1007/s00276-013-1240-z

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  21 in total

1.  The intra-osseous vasculature of the distal end of the humerus with special reference to capitulum; preliminary communication.

Authors:  S HARALDSSON
Journal:  Acta Orthop Scand       Date:  1957

2.  Location, number and clinical significance of nutrient foramina in human long bones.

Authors:  Emine Kizilkanat; Neslihan Boyan; Esin T Ozsahin; Roger Soames; Ozkan Oguz
Journal:  Ann Anat       Date:  2007       Impact factor: 2.698

3.  Intraosseous blood supply to the distal humerus.

Authors:  Jon P Kimball; Frank Glowczewskie; Thomas W Wright
Journal:  J Hand Surg Am       Date:  2007 May-Jun       Impact factor: 2.230

4.  The microvascular anatomy of the metatarsal bones: a plastination study.

Authors:  Björn Rath; Hans-Peter Notermans; Jan Franzen; Jutta Knifka; Jürgen Walpert; Daniel Frank; Jürgen Koebke
Journal:  Surg Radiol Anat       Date:  2008-11-21       Impact factor: 1.246

5.  Parallel plate fixation of bicolumn distal humeral fractures.

Authors:  Shawn W O'Driscoll
Journal:  Instr Course Lect       Date:  2009

6.  The extraosseous and intraosseous arterial anatomy of the adult elbow.

Authors:  K Yamaguchi; F A Sweet; R Bindra; B F Morrey; R H Gelberman
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

7.  Optimizing stability in distal humeral fracture fixation.

Authors:  Shawn W O'Driscoll
Journal:  J Shoulder Elbow Surg       Date:  2005 Jan-Feb       Impact factor: 3.019

8.  Osteonecrosis after open reduction and internal fixation of a bicolumnar fracture of the distal humerus: a report of four cases.

Authors:  Jimme K Wiggers; David Ring
Journal:  J Hand Surg Am       Date:  2010-11-05       Impact factor: 2.230

9.  Intraarticular distal humerus fractures. Factors affecting functional outcome.

Authors:  K Kundel; W Braun; J Wieberneit; A Rüter
Journal:  Clin Orthop Relat Res       Date:  1996-11       Impact factor: 4.176

10.  A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

Authors:  Jan Korner; Gerd Diederichs; Michael Arzdorf; Helmut Lill; Christoph Josten; Erich Schneider; Berend Linke
Journal:  J Orthop Trauma       Date:  2004 May-Jun       Impact factor: 2.512

View more
  6 in total

1.  Presentation of the vascular supply of the proximal ulna using a sequential plastination technique.

Authors:  Thomas C Koslowsky; V Berger; J C Hopf; L P Müller
Journal:  Surg Radiol Anat       Date:  2015-04-18       Impact factor: 1.246

2.  Novel fixation of medial epicondyle fractures in a throwing athlete using suture bridge technique.

Authors:  Sunny Gupta; Benjamin C Service; Jordan Service; Ibrahim M Zeini; Daryl C Osbahr
Journal:  JSES Int       Date:  2020-11-23

3.  Partially intraosseous schwannoma of the distal humerus with increased enhancement after biopsy: Radiologic-pathologic correlation.

Authors:  Shan S Hansra; Colin N Brown; Lisa H Kang; Kurt B Schaberg; Steven W Thorpe; Dillon C Chen
Journal:  Radiol Case Rep       Date:  2022-02-04

4.  A NEW ANATOMICAL PLATE FOR EXTRA-ARTICULAR DISTAL HUMERAL FRACTURES: BIOMECHANICAL STUDY.

Authors:  Harun Mutlu; Abdulkadir Polat; Mehmet Ümit Çetin; Serhat Mutlu; Teyfik Demir; Atilla Sancar Parmaksizoğlu
Journal:  Acta Ortop Bras       Date:  2022-01-28       Impact factor: 0.513

5.  Osseous Vascularity of the Medial Elbow After Ulnar Collateral Ligament Reconstruction: A Comparison of the Docking and Modified Jobe Techniques.

Authors:  Christopher L Camp; Craig E Klinger; Lionel E Lazaro; Jordan C Villa; Jelle P van der List; David W Altchek; Dean G Lorich; Joshua S Dines
Journal:  Orthop J Sports Med       Date:  2018-04-02

6.  Three-dimensional topography of scapular nutrient foramina.

Authors:  J C E Donders; J Prins; P Kloen; G J Streekstra; P A Cole; R P Kleipool; J G G Dobbe
Journal:  Surg Radiol Anat       Date:  2020-02-28       Impact factor: 1.246

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.