Literature DB >> 21133379

24-hour lock mass protection.

Kimberly A Lee1, Chris Farnsworth, Wen Yu, Leo E Bonilla.   

Abstract

The positive role and application of highly accurate mass measurements in proteomics is well documented. The new generation of hybrid FTMS and Q-TOF instruments, including the LTQ-Orbitrap (OT), is remarkable in their ability to routinely produce single-digit to subppm statistical mass accuracy while maintaining high analytical sensitivity. The use of mass calibrants (lock masses) to reduce the systematic error of mass-to-charge measurements has also been reported and, in some cases, incorporated in the instrument control software by the instrument manufacturers. We evaluated the use of one such calibrant in the OT (e.g., polydimethylcyclosiloxane, PCM) to study its impact on the rate of phosphopeptide annotation and found it to lack robustness under normal laboratory conditions. Therefore, we devised a strategy to improve its performance by increasing the external abundance of calibrant molecules in laboratory air. This resulted in a more robust performance of the preprogrammed lock mass recalibration feature as evidenced by improvements in both statistical mass accuracy and peptide annotation rates.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21133379     DOI: 10.1021/pr100780b

Source DB:  PubMed          Journal:  J Proteome Res        ISSN: 1535-3893            Impact factor:   4.466


  7 in total

1.  Data analysis strategy for maximizing high-confidence protein identifications in complex proteomes such as human tumor secretomes and human serum.

Authors:  Huan Wang; Hsin-Yao Tang; Glenn C Tan; David W Speicher
Journal:  J Proteome Res       Date:  2011-10-18       Impact factor: 4.466

Review 2.  Phosphoproteomic analysis: an emerging role in deciphering cellular signaling in human embryonic stem cells and their differentiated derivatives.

Authors:  Brian T D Tobe; Junjie Hou; Andrew M Crain; Ilyas Singec; Evan Y Snyder; Laurence M Brill
Journal:  Stem Cell Rev Rep       Date:  2012-03       Impact factor: 5.739

Review 3.  Protein analysis by shotgun/bottom-up proteomics.

Authors:  Yaoyang Zhang; Bryan R Fonslow; Bing Shan; Moon-Chang Baek; John R Yates
Journal:  Chem Rev       Date:  2013-02-26       Impact factor: 60.622

4.  Using ProtMAX to create high-mass-accuracy precursor alignments from label-free quantitative mass spectrometry data generated in shotgun proteomics experiments.

Authors:  Volker Egelhofer; Wolfgang Hoehenwarter; David Lyon; Wolfram Weckwerth; Stefanie Wienkoop
Journal:  Nat Protoc       Date:  2013-02-28       Impact factor: 13.491

5.  Mass accuracy and isotopic abundance measurements for HR-MS instrumentation: capabilities for non-targeted analyses.

Authors:  Ann M Knolhoff; John H Callahan; Timothy R Croley
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-12       Impact factor: 3.109

6.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

7.  Flux Analysis of Free Amino Sugars and Amino Acids in Soils by Isotope Tracing with a Novel Liquid Chromatography/High Resolution Mass Spectrometry Platform.

Authors:  Yuntao Hu; Qing Zheng; Wolfgang Wanek
Journal:  Anal Chem       Date:  2017-08-22       Impact factor: 6.986

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.