Literature DB >> 21129876

In vivo SNR in DENSE MRI; temporal and regional effects of field strength, receiver coil sensitivity and flip angle strategies.

Andreas Sigfridsson1, Henrik Haraldsson, Tino Ebbers, Hans Knutsson, Hajime Sakuma.   

Abstract

AIM: The influences on the signal-to-noise ratio (SNR) of Displacement ENcoding with Stimulated Echoes (DENSE) MRI of field strength, receiver coil sensitivity and choice of flip angle strategy have been previously investigated individually. In this study, all of these parameters have been investigated in the same setting, and a mutual comparison of their impact on SNR is presented.
MATERIALS AND METHODS: Ten healthy volunteers were imaged in a 1.5 T and a 3 T MRI system, using standard five- or six-channel cardiac coils as well as 32-channel coils, with four different excitation patterns. Variation of spatial coil sensitivity was assessed by regional SNR analysis.
RESULTS: SNR ranging from 2.8 to 30.5 was found depending on the combination of excitation patterns, coil sensitivity and field strength. The SNR at 3 T was 53±26% higher than at 1.5 T (P<.001), whereas spatial differences of 59±26% were found in the ventricle (P<.001). Thirty-two-channel coils provided 52±29% higher SNR compared to standard five- or six-channel coils (P<.001). A fixed flip angle strategy provided an excess of 50% higher SNR in half of the imaged cardiac cycle compared to a sweeping flip angle strategy, and a single-phase acquisition provided a sixfold increase of SNR compared to a cine acquisition.
CONCLUSION: The effect of field strength and receiver coil sensitivity influences the SNR with the same order of magnitude, whereas flip angle strategy can have a larger effect on SNR. Thus, careful choice of imaging hardware in combination with adaptation of the acquisition protocol is crucial in order to realize sufficient SNR in DENSE MRI.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21129876     DOI: 10.1016/j.mri.2010.08.016

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  11 in total

1.  Quantitative assessment of myocardial strain with displacement encoding with stimulated echoes MRI in patients with coronary artery disease.

Authors:  Hideki Miyagi; Motonori Nagata; Kakuya Kitagawa; Shingo Kato; Shinichi Takase; Andreas Sigfridsson; Masaki Ishida; Kaoru Dohi; Masaaki Ito; Hajime Sakuma
Journal:  Int J Cardiovasc Imaging       Date:  2013-08-10       Impact factor: 2.357

Review 2.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

3.  Optimal configuration of respiratory navigator gating for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI.

Authors:  Sean M Hamlet; Christopher M Haggerty; Jonathan D Suever; Gregory J Wehner; Kristin N Andres; David K Powell; Xiaodong Zhong; Brandon K Fornwalt
Journal:  J Magn Reson Imaging       Date:  2016-07-26       Impact factor: 4.813

4.  Systolic myocardial dysfunction in patients with type 2 diabetes mellitus: identification at MR imaging with cine displacement encoding with stimulated echoes.

Authors:  Laura Ernande; Hélène Thibault; Cyrille Bergerot; Phillippe Moulin; Han Wen; Geneviève Derumeaux; Pierre Croisille
Journal:  Radiology       Date:  2012-08-28       Impact factor: 11.105

5.  Myocardial strains from 3D displacement encoded magnetic resonance imaging.

Authors:  Katarina Kindberg; Henrik Haraldsson; Andreas Sigfridsson; Jan Engvall; Neil B Ingels; Tino Ebbers; Matts Karlsson
Journal:  BMC Med Imaging       Date:  2012-04-25       Impact factor: 1.930

6.  Clinical experience of strain imaging using DENSE for detecting infarcted cardiac segments.

Authors:  Johan Kihlberg; Henrik Haraldsson; Andreas Sigfridsson; Tino Ebbers; Jan E Engvall
Journal:  J Cardiovasc Magn Reson       Date:  2015-06-24       Impact factor: 5.364

7.  Feasibility of asymmetric stretch assessment in the ascending aortic wall with DENSE cardiovascular magnetic resonance.

Authors:  Henrik Haraldsson; Michael Hope; Gabriel Acevedo-Bolton; Elaine Tseng; Xiaodong Zhong; Frederick H Epstein; Liang Ge; David Saloner
Journal:  J Cardiovasc Magn Reson       Date:  2014-01-09       Impact factor: 5.364

8.  Validation of in vivo 2D displacements from spiral cine DENSE at 3T.

Authors:  Gregory J Wehner; Jonathan D Suever; Christopher M Haggerty; Linyuan Jing; David K Powell; Sean M Hamlet; Jonathan D Grabau; Walter Dimitri Mojsejenko; Xiaodong Zhong; Frederick H Epstein; Brandon K Fornwalt
Journal:  J Cardiovasc Magn Reson       Date:  2015-01-30       Impact factor: 5.364

9.  Quantifying cardiac-induced brain tissue expansion using DENSE.

Authors:  Ayodeji L Adams; Hugo J Kuijf; Max A Viergever; Peter R Luijten; Jaco J M Zwanenburg
Journal:  NMR Biomed       Date:  2018-12-21       Impact factor: 4.044

10.  2D cine DENSE with low encoding frequencies accurately quantifies cardiac mechanics with improved image characteristics.

Authors:  Gregory J Wehner; Jonathan D Grabau; Jonathan D Suever; Christopher M Haggerty; Linyuan Jing; David K Powell; Sean M Hamlet; Moriel H Vandsburger; Xiaodong Zhong; Brandon K Fornwalt
Journal:  J Cardiovasc Magn Reson       Date:  2015-11-04       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.