Literature DB >> 21128103

Study of enhanced chemiluminescence of diperiodatocuprate (III) on 1,10-phenanthroline/hydrogen peroxide/cetyltrimethylammonium bromide system.

Jing Kang1, Jieli Tang, Lu Han, Yihua Zhang.   

Abstract

In the paper, a chemiluminescence (CL) system was developed based on the catalytical effect of diperiodatocuprate (III) (DPC) on the 1,10-phenanthroline (phen)/hydrogen peroxide (H(2)O(2)) in the presence of cetyltrimethylammonium bromide (CTAB). The effects of experimental conditions were investigated. Meanwhile the increase of CL intensity of the DPC/phen/H(2)O(2)/CTAB system is proportional to the concentration of phen in the range of low concentration. The linear range of the calibration curve is 5.0 × 10(-9)-1.0 × 10(-6) mol L(-1), and the corresponding detection limit is 1.9 × 10(-9) mol L(-1). The effects of phenolic compounds (PCs) on the system were investigated. Hydroquinone was used as an example to investigate the application of the CL system to the determination of PCs. The quenched CL intensity is linearly related to the logarithm of concentration of hydroquinone. The linear range of the calibration curve is 2.5 × 10(-9)-1.0 × 10(-5) g mL(-1), and the corresponding detection limit is 1.8 × 10(-9) g mL(-1). This phen and hydroquinone can be synchronously determined. The method was applied to the determination of hydroquinone in water samples and the recoveries were from 92% to 106%. © Springer Science+Business Media, LLC 2010

Entities:  

Year:  2010        PMID: 21128103     DOI: 10.1007/s10895-010-0774-2

Source DB:  PubMed          Journal:  J Fluoresc        ISSN: 1053-0509            Impact factor:   2.217


  10 in total

1.  Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection.

Authors:  H Cui; C He; G Zhao
Journal:  J Chromatogr A       Date:  1999-09-03       Impact factor: 4.759

2.  Molecular fluorescence, phosphorescence, and chemiluminescence spectrometry.

Authors:  Kristin A Fletcher; Sayo O Fakayode; Mark Lowry; Sheryl A Tucker; Sharon L Neal; Irene W Kimaru; Matthew E McCarroll; Gabor Patonay; Philip B Oldham; Oleksandr Rusin; Robert M Strongin; Isiah M Warner
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

Review 3.  Applications of the luminol chemiluminescent reaction in analytical chemistry.

Authors:  Christophe A Marquette; Loïc J Blum
Journal:  Anal Bioanal Chem       Date:  2006-05-03       Impact factor: 4.142

4.  Flow-injection chemiluminescence determination of chlortetracycline using on-line electrogenerated [Cu(HIO(6))(2)](5-) as the oxidant.

Authors:  B Li; Z Zhang; W Liu
Journal:  Talanta       Date:  2001-12-24       Impact factor: 6.057

5.  Carbon dioxide effects on luminol and 1,10-phenanthroline chemiluminescence.

Authors:  Caibin Xiao; Donald A Palmer; David J Wesolowski; Sara B Lovitz; D Whitney King
Journal:  Anal Chem       Date:  2002-05-01       Impact factor: 6.986

6.  Sensitized chemiluminescence of Tween 20 on CdTe/H(2)O(2) and its analytical applications for determination of phenolic compounds.

Authors:  Jing Kang; Juan Li; Jieli Tang; Minjie Li; Xiaozhou Li; Yihua Zhang
Journal:  Colloids Surf B Biointerfaces       Date:  2009-11-14       Impact factor: 5.268

7.  Direct detection of biomolecules in a capillary electrophoresis-chemiluminescence detection system.

Authors:  Kazuhiko Tsukagoshi; Koji Nakahama; Riichiro Nakajima
Journal:  Anal Chem       Date:  2004-08-01       Impact factor: 6.986

8.  Determination of free cholesterol based on a novel flow-injection chemiluminescence method by immobilizing enzyme.

Authors:  Yufei Hu; Zhujun Zhang
Journal:  Luminescence       Date:  2008 Sep-Oct       Impact factor: 2.464

9.  Development of an analytical method for the determination of beta2-agonist residues in animal tissues by high-performance liquid chromatography with on-line electrogenerated [Cu(HIO6)2]5- -luminol chemiluminescence detection.

Authors:  Yantu Zhang; Zhujun Zhang; Yonghua Sun; Yue Wei
Journal:  J Agric Food Chem       Date:  2007-05-31       Impact factor: 5.279

10.  The determination of hydrogen peroxide generated from cigarette smoke with an ultrasensitive and highly selective chemiluminescence method.

Authors:  Yufei Hu; Zhujun Zhang; Chunyan Yang
Journal:  Anal Chim Acta       Date:  2007-08-19       Impact factor: 6.558

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.