Literature DB >> 21115134

MiraLAX is not as effective as GoLytely in bowel cleansing before screening colonoscopies.

Michael Hjelkrem1, Joel Stengel, Mark Liu, David P Jones, Stephen A Harrison.   

Abstract

BACKGROUND & AIMS: Successful colonoscopies require good bowel preparations-poor bowel preparations can increase medical costs, rates of missed lesions, and procedure duration. The combination of polyethylene glycol (PEG) 3350 without electrolytes (MiraLAX; Schering-Plough Healthcare Products, Inc, Kenilworth, NJ) and 64 oz of Gatorade (PepsiCo, Inc, Purchase, NY) has gained popularity as a bowel preparation regimen. However, the efficacy and tolerability of this approach has not been compared with standard bowel preparations in clinical trials. We compared split-dose (PEG) 3350 with electrolytes (GoLytely; Braintree Laboratories, Inc, Braintree, MA) with split-dose MiraLAX alone and in combination with pretreatment medications (bisacodyl or lubiprostone) to determine the efficacy and patient tolerability of MiraLAX as an agent for bowel preparation.
METHODS: We performed a prospective, randomized, blinded, controlled trial at a tertiary care center. Patients (n=403) were randomly assigned to groups given GoLytely, MiraLAX, MiraLAX with bisacodyl (10 mg), or MiraLAX with lubiprostone (24 μg). MiraLAX was combined with 64 oz of Gatorade. All patients were surveyed regarding preparation satisfaction and tolerability. The Ottawa bowel preparation scale was used to grade colon cleanliness.
RESULTS: GoLytely was more effective at bowel cleansing (average Ottawa score, 5.1) than MiraLAX alone (average Ottawa score, 6.9) or in combination with lubiprostone (average Ottawa score, 6.8), or bisacodyl (average Ottawa score, 6.3) (P<.001). MiraLAX was associated with a trend toward longer procedure duration (P=.096). Groups given MiraLAX rated the overall experience as more satisfactory than those given GoLytely (P<.001). There were no differences between polyp detection rates (P=.346) or adverse events (P=.823).
CONCLUSIONS: Split-dose MiraLAX in 64 oz of Gatorade is not as effective as 4 L split-dose GoLytely in bowel cleansing for screening colonoscopies.
Copyright © 2011 AGA Institute. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21115134     DOI: 10.1016/j.cgh.2010.11.007

Source DB:  PubMed          Journal:  Clin Gastroenterol Hepatol        ISSN: 1542-3565            Impact factor:   11.382


  16 in total

Review 1.  Colon cleansing for colonoscopy 2013: current status.

Authors:  Stephen W Landreneau; Jack A Di Palma
Journal:  Curr Gastroenterol Rep       Date:  2013-08

2.  Nationwide variability of colonoscopy preparation instructions.

Authors:  Loc Ton; Helen Lee; Pushpak Taunk; Audrey H Calderwood; Brian C Jacobson
Journal:  Dig Dis Sci       Date:  2014-07-02       Impact factor: 3.199

3.  Comparing the Real-World Effectiveness of Competing Colonoscopy Preparations: Results of a Prospective Trial.

Authors:  Phillip Gu; Daniel Lew; Sun Jung Oh; Aarshi Vipani; Jeffrey Ko; Kevin Hsu; Ebrahim Mirakhor; Varun Pattisapu; Tia Bullen; Garth Fuller; Brennan M R Spiegel; Christopher V Almario
Journal:  Am J Gastroenterol       Date:  2019-02       Impact factor: 10.864

4.  Split-dose menthol-enhanced PEG vs PEG-ascorbic acid for colonoscopy preparation.

Authors:  Ala I Sharara; Ali H Harb; Fayez S Sarkis; Jean M Chalhoub; Rami Badreddine; Fadi H Mourad; Mahmoud Othman; Omar Masri
Journal:  World J Gastroenterol       Date:  2015-02-14       Impact factor: 5.742

Review 5.  Bowel cleansing before colonoscopy: Balancing efficacy, safety, cost and patient tolerance.

Authors:  Nicole M Harrison; Michael C Hjelkrem
Journal:  World J Gastrointest Endosc       Date:  2016-01-10

6.  Colonoscopy preparation: polyethylene glycol with Gatorade is as safe and efficacious as four liters of polyethylene glycol with balanced electrolytes.

Authors:  Thomas McKenna; Alice Macgill; Gail Porat; Frank K Friedenberg
Journal:  Dig Dis Sci       Date:  2012-06-19       Impact factor: 3.199

Review 7.  Quality indicators for colonoscopy: Current insights and caveats.

Authors:  Hendrikus Jm Pullens; Peter D Siersema
Journal:  World J Gastrointest Endosc       Date:  2014-12-16

8.  Predictors of suboptimal bowel preparation in asymptomatic patients undergoing average-risk screening colonoscopy.

Authors:  Shail M Govani; Eric E Elliott; Stacy B Menees; Stephanie L Judd; Sameer D Saini; Constantinos P Anastassiades; Annette L Urganus; Suzanna J Boyce; Philip S Schoenfeld
Journal:  World J Gastrointest Endosc       Date:  2016-09-16

9.  Split dose and MiraLAX-based purgatives to enhance bowel preparation quality becoming common recommendations in the US.

Authors:  Grace Clarke Hillyer; Benjamin Lebwohl; Corey H Basch; Charles E Basch; Fay Kastrinos; Beverly J Insel; Alfred I Neugut
Journal:  Therap Adv Gastroenterol       Date:  2013-01       Impact factor: 4.409

10.  MiraLAX-Gatorade bowel prep versus GoLytely before screening colonoscopy: an endoscopic database study in a community hospital.

Authors:  Frederick K Shieh; Naresh Gunaratnam; Sagal O Mohamud; Philip Schoenfeld
Journal:  J Clin Gastroenterol       Date:  2012 Nov-Dec       Impact factor: 3.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.