Literature DB >> 21111309

Comparison of visual performance with blue light-filtering and ultraviolet light-filtering intraocular lenses.

Beatrix Neumaier-Ammerer1, Stefan Felke, Stefan Hagen, Paulina Haas, Florian Zeiler, Harald Mauler, Susanne Binder.   

Abstract

PURPOSE: To compare the contrast sensitivity, glare, color perception, and visual acuity at different light intensities with yellow-tinted and clear intraocular lenses (IOLs) by different manufacturers.
SETTING: Ludwig Boltzmann Institute of Retinology and Biomicroscopic Laser-Surgery, Department of Ophthalmology, Rudolf Foundation Clinic, Vienna, Austria.
DESIGN: Comparative case series.
METHODS: Eyes were randomized to 1 of the following IOLs: AF-1 (UY) (yellow tinted), AcrySof SN60AT (yellow tinted), AF-1 (UV) (clear), or AcrySof SA60AT (clear). One week and 2 months postoperatively, monocular contrast sensitivity function and color discrimination were tested and the corrected distance and near visual acuities were evaluated. All tests were performed under different light intensities (10 to 1000 lux).
RESULTS: Of the 80 patients enrolled, 76 completed the study; there were 37 eyes in the yellow-tinted IOL group and 39 in the clear IOL group. There were no significant differences between yellow-tinted IOLs and clear IOLs except in color vision under mesopic conditions (10 lux). Patients with a yellow-tinted IOL made significantly more mistakes in the blue-light spectrum than patients with clear IOLs (P = .00015). There was no significant difference under photopic conditions (1000 lux).
CONCLUSIONS: The yellow-tinted IOLs were equivalent to the clear IOLs in postoperative contrast sensitivity, visual acuity, and color perception under photopic conditions. Patients with yellow-tinted IOLs made statistically significantly more mistakes in the blue range under dim light than patients with clear IOLs.
Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21111309     DOI: 10.1016/j.jcrs.2010.06.069

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  Effect on contrast sensitivity after clear, yellow and orange intraocular lens implantation.

Authors:  Sabyasachi Bandyopadhyay; Mita Saha; Asim Chakrabarti; Abhik Sinha
Journal:  Int Ophthalmol       Date:  2015-08-19       Impact factor: 2.031

2.  Effect of blue light-filtering intraocular lens on color vision in patients with macular diseases after vitrectomy.

Authors:  Kumiko Mokuno; Tetsu Asami; Norie Nonobe; Hirotaka Ito; Kumi Fujiwara; Hiroko Terasaki
Journal:  Int Ophthalmol       Date:  2016-03-11       Impact factor: 2.031

3.  Role of short-wavelength filtering lenses in delaying myopia progression and amelioration of asthenopia in juveniles.

Authors:  Hai-Lan Zhao; Jin Jiang; Jie Yu; Hai-Ming Xu
Journal:  Int J Ophthalmol       Date:  2017-08-18       Impact factor: 1.779

Review 4.  Recent studies provide an updated clinical perspective on blue light-filtering IOLs.

Authors:  James A Davison; Anil S Patel; Joao P Cunha; Jim Schwiegerling; Orkun Muftuoglu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-05-17       Impact factor: 3.117

Review 5.  Comparison of blue light-filtering IOLs and UV light-filtering IOLs for cataract surgery: a meta-analysis.

Authors:  Xiao-feng Zhu; Hai-dong Zou; Yong-fu Yu; Qian Sun; Nai-qing Zhao
Journal:  PLoS One       Date:  2012-03-07       Impact factor: 3.240

Review 6.  Blue-light filtering intraocular lenses (IOLs) for protecting macular health.

Authors:  Laura E Downie; Ljoudmila Busija; Peter R Keller
Journal:  Cochrane Database Syst Rev       Date:  2018-05-22

7.  Attenuating Photostress and Glare Disability in Pseudophakic Patients through the Addition of a Short-Wave Absorbing Filter.

Authors:  Billy R Hammond
Journal:  J Ophthalmol       Date:  2015-03-09       Impact factor: 1.909

Review 8.  The Influence of Intraocular Lenses (IOLs) on the Properties of Filters Protecting Human Eyes against Optical Radiation in the Work Environment.

Authors:  Grzegorz Owczarek; Joanna Szkudlarek; Natalia Skuza
Journal:  Int J Environ Res Public Health       Date:  2022-02-04       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.