Literature DB >> 21105615

Accuracy and upgrade rates of percutaneous breast biopsy: the surgeon's role.

Windy Olaya1, Won Bae, Jan Wong, Jasmine Wong, Sharmila Roy-Chowdhury, Kevork Kazanjian, Sharon Lum.   

Abstract

We sought to evaluate the impact of needle core size and number of core samples on diagnostic accuracy and upgrade rates for image-guided core needle biopsies of the breast. A total of 234 patients underwent image-guided percutaneous needle biopsies and subsequent surgical excision. Large-core needles (9 gauge or less) were used in 14.5 per cent of cases and the remainder were performed with smaller core needles. More than four core samples were taken in 78.9 per cent of patients. In 71.8 per cent of cases, needle biopsy pathology matched surgical excision pathology. After surgical excision, upgraded pathology was revealed in 10.7 per cent of cases. Of 11 patients (52.4%) with benign needle core pathology who had upgraded final pathology on surgical excision, 10 had a Breast Imaging Recording and Data System score 4 or 5 imaging study. Lesions smaller than 10 mm were more likely to be misdiagnosed (P = 0.01) or have upgraded pathology (P = 0.009). Other predictors of upgraded pathology were patient age 50 years or older (P = 0.03) and taking four or fewer core samples (P = 0.003). Needle core size did not impact accuracy or upgrade rates. Surgeons should exercise caution when interpreting needle biopsy results with older patients, smaller lesions, and limited sampling. Discordant pathology and imaging still mandate surgical confirmation.

Entities:  

Mesh:

Year:  2010        PMID: 21105615

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  3 in total

1.  Integration of the OpenIGTLink network protocol for image-guided therapy with the medical platform MeVisLab.

Authors:  Jan Egger; Junichi Tokuda; Laurent Chauvin; Bernd Freisleben; Christopher Nimsky; Tina Kapur; William Wells
Journal:  Int J Med Robot       Date:  2012-02-28       Impact factor: 2.547

2.  Lesions of uncertain malignant potential (B3) on core biopsy in the NHS Breast Screening Programme: is the screening round relevant?

Authors:  R J Hunt; J R Steel; G J R Porter; C S Holgate; R M Watkins
Journal:  Ann R Coll Surg Engl       Date:  2012-03       Impact factor: 1.891

3.  Utilization of Percutaneous Needle Biopsy for Breast Diagnosis in a Comprehensive Breast Center: Implications for Development of Quality Indicators.

Authors:  Claire M B Holloway; Lolwah Al-Riyees; Refik Saskin
Journal:  World J Surg       Date:  2016-07       Impact factor: 3.352

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.