Comprehensive dose survey of breast screening in Ireland.

P Baldelli1, J McCullagh, N Phelan, F Flanagan.   

Abstract

The primary purpose of this study was to evaluate the impact of digital mammography screening on breast dose by analysing the results of a patient dose survey of the Irish breast screening programme. Results from the survey were used to determine a dose reference level for the screening programme. Approximately, 100 examinations were acquired for each of the digital mammography systems operational in the screening programme. Each examination consisted of two standard views of each breast. The mean glandular dose for each acquired image was calculated. The dose reference level was established by calculating the 95th percentile of the average mean glandular dose for the average compressed breast thickness of the mediolateral oblique views. The overall average mean glandular dose per examination was 2.72 ± 0.04 mGy. The average compressed breast thickness was 61.4 ± 0.03 mm. The average compression force was 109 ± 7 N. A dose reference level value of 1.75 mGy was established for the screening programme. The results of this clinical dose survey provide a valuable indication of the dose performance of modern full field digital mammographic imaging systems. The results demonstrate clearly the dose benefits of digital mammography. The dose benefit of digital screening was further demonstrated by the establishment of a comparatively lower diagnostic reference level for the screening programme. The comparison of the dose performance of individual X-ray systems with the diagnostic reference level highlights the need for more optimisation within the service.

Entities:  

Mesh:

Year:  2010        PMID: 21097483     DOI: 10.1093/rpd/ncq375

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Comparison of the clinical performance of three digital mammography systems in a breast cancer screening programme.

Authors:  E Keavey; N Phelan; A M O'Connell; F Flanagan; A O'Doherty; A Larke; A M Connors
Journal:  Br J Radiol       Date:  2011-11-17       Impact factor: 3.039

2.  Scatter radiation intensities around full-field digital mammography units.

Authors:  M A Judge; E Keavey; N Phelan
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

Review 3.  Beyond mammography: new frontiers in breast cancer screening.

Authors:  Jennifer S Drukteinis; Blaise P Mooney; Chris I Flowers; Robert A Gatenby
Journal:  Am J Med       Date:  2013-04-03       Impact factor: 4.965

4.  The Impact of Acquisition Dose on Quantitative Breast Density Estimation with Digital Mammography: Results from ACRIN PA 4006.

Authors:  Lin Chen; Shonket Ray; Brad M Keller; Said Pertuz; Elizabeth S McDonald; Emily F Conant; Despina Kontos
Journal:  Radiology       Date:  2016-03-22       Impact factor: 11.105

Review 5.  Update on new technologies in digital mammography.

Authors:  Stephanie K Patterson; Marilyn A Roubidoux
Journal:  Int J Womens Health       Date:  2014-08-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.