Literature DB >> 21096980

Artifact reduction based on Empirical Mode Decomposition (EMD) in photoplethysmography for pulse rate detection.

Qian Wang1, Ping Yang, Yuanting Zhang.   

Abstract

The pulstile components of photoplethysmography (PPG) contain valuable information about a subject's cardiovascular and metabolic systems. Pulse rate is one of the most significant vital signs that can be extracted from PPG signals. However, patient movement, especially movement at the measurement sites, such as fingers, can disturb the PPG's light path significantly, resulting in corrupted measurements. In this paper, a method is proposed for removing motion artifacts from PPG recordings. In this method, the Empirical Mode Decomposition (EMD) and Hilbert transform are used together to decompose PPG recordings into instantaneous frequency series on different scales of resolution. Motion artifacts and physiological signals are separated based on these series. The proposed method was used to recover PPG signals recorded in an experiment, where motion artifacts were intentionally introduced by finger bending. By using our method, the signal-to-noise ratio was increased from 0.078 dB of the contaminated signals to 0.318 dB, and the true detection rate of heartbeats was improved from 59.2% to 96.6%. The results demonstrated that the EMD combined with Hilbert transform has great potential in reducing motion artifacts in PPG signals and can improve the accuracy of heartbeat detection.

Entities:  

Mesh:

Year:  2010        PMID: 21096980     DOI: 10.1109/IEMBS.2010.5627581

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  4 in total

1.  Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter.

Authors:  Fulai Peng; Zhengbo Zhang; Xiaoming Gou; Hongyun Liu; Weidong Wang
Journal:  Biomed Eng Online       Date:  2014-04-24       Impact factor: 2.819

Review 2.  Novel Flexible Wearable Sensor Materials and Signal Processing for Vital Sign and Human Activity Monitoring.

Authors:  Amir Servati; Liang Zou; Z Jane Wang; Frank Ko; Peyman Servati
Journal:  Sensors (Basel)       Date:  2017-07-13       Impact factor: 3.576

Review 3.  Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review.

Authors:  Luwei Nie; Daniel Berckmans; Chaoyuan Wang; Baoming Li
Journal:  Sensors (Basel)       Date:  2020-04-17       Impact factor: 3.576

4.  SPARE: A Spectral Peak Recovery Algorithm for PPG Signals Pulsewave Reconstruction in Multimodal Wearable Devices.

Authors:  Giulio Masinelli; Fabio Dell'Agnola; Adriana Arza Valdés; David Atienza
Journal:  Sensors (Basel)       Date:  2021-04-13       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.