Literature DB >> 21095833

Diamond penetrating electrode array for epi-retinal prosthesis.

K Ganesan1, A Stacey, H Meffin, S Lichter, U Greferath, E L Fletcher, S Prawer.   

Abstract

This paper presents progress in the characterization and application of diamond penetrating electrode arrays for Epi-Retinal Prostheses. Electrical stimulation of degenerate retina has already been shown to restore partial vision for some blind patients, albeit at low spatial resolution. Higher resolution may be achievable by building arrays with electrodes that have greater areal density and closer proximity to target neurons. However, high standards of biocompatibility and hermeticity must be maintained, limiting the range of available materials of manufacture. Here, the design and histology of high density electrode arrays (approximately 100 electrodes/mm(2)) made from polycrystalline diamond and implanted into rat retinae are discussed. Results from initial steps in this process are reported.

Entities:  

Mesh:

Year:  2010        PMID: 21095833     DOI: 10.1109/IEMBS.2010.5626003

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  5 in total

1.  Selectivity of direct and network-mediated stimulation of the retinal ganglion cells with epi-, sub- and intraretinal electrodes.

Authors:  David Boinagrov; Susanne Pangratz-Fuehrer; Georges Goetz; Daniel Palanker
Journal:  J Neural Eng       Date:  2014-03-10       Impact factor: 5.379

2.  Vertically integrated photo junction-field-effect transistor pixels for retinal prosthesis.

Authors:  Samir Damle; Yu-Hsin Liu; Shaurya Arya; Nicholas W Oesch; Yu-Hwa Lo
Journal:  Biomed Opt Express       Date:  2019-12-04       Impact factor: 3.732

3.  Temperature control at DBS electrodes using a heat sink: experimentally validated FEM model of DBS lead architecture.

Authors:  Maged M Elwassif; Abhishek Datta; Asif Rahman; Marom Bikson
Journal:  J Neural Eng       Date:  2012-07-04       Impact factor: 5.379

4.  Implantation and Extraction of Penetrating Electrode Arrays in Minipig Retinas.

Authors:  Jinghua Chen; Vasiliki Poulaki; Seong-Joon Kim; William D Eldred; Sheryl Kane; Marcus Gingerich; Douglas B Shire; Ralph Jensen; Gloria DeWalt; Henry J Kaplan; Joseph F Rizzo
Journal:  Transl Vis Sci Technol       Date:  2020-04-24       Impact factor: 3.283

5.  Minimizing Iridium Oxide Electrodes for High Visual Acuity Subretinal Stimulation.

Authors:  Samir Damle; Maya Carleton; Theodoros Kapogianis; Shaurya Arya; Melina Cavichini-Corderio; William R Freeman; Yu-Hwa Lo; Nicholas W Oesch
Journal:  eNeuro       Date:  2021-12-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.