Literature DB >> 21092970

Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

Rachel C Paietta1, Sara E Campbell, Virginia L Ferguson.   

Abstract

Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips of R=5, 25, 65, and 200 μm. Nanoindentation arrays, not targeted to fall on specific structures or locations, enabled statistical sampling of osteons within PMMA-embedded, bovine, cortical bone on a single sample to a range of maximum displacements (minimum of 100 nm and maximum of 2000 nm). Elastic finite element models were then utilized to isolate the contributions of indenter tip radius, contact area, and position within the lamellar structure in comparison to the experimental results. For a small, R=5 μm indenter tip, indentation modulus consistently increased with contact depth and increased plastic deformation, resulting in an artificial increase in elastic properties. While larger radius tips (R=25, 65, and 200 μm) did not enable evaluation of a high spatial resolution on the surface, they produced data that was representative of the lower load and contact depth measurements with the smaller tip. However the sensitivity to mechanical property variations across the 2-D surface of the material was lost with increase in indenter tip size. Correspondingly, measurement variance was also decreased as the volume contributing to the indent response represented an average of surface roughness, varying mineral content, defects, and underlying tissue type and structure.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21092970     DOI: 10.1016/j.jbiomech.2010.10.008

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Spatial localization of mechanical excitation affects spatial resolution, contrast, and contrast-to-noise ratio in acoustic radiation force optical coherence elastography.

Authors:  Nichaluk Leartprapun; Rishyashring R Iyer; Colin D Mackey; Steven G Adie
Journal:  Biomed Opt Express       Date:  2019-10-24       Impact factor: 3.732

2.  Deleterious effects of osteoarthritis on the structure and function of the meniscal enthesis.

Authors:  A C Abraham; H M Pauly; T L Haut Donahue
Journal:  Osteoarthritis Cartilage       Date:  2013-12-05       Impact factor: 6.576

3.  Moderate chronic kidney disease impairs bone quality in C57Bl/6J mice.

Authors:  Chelsea M Heveran; Alicia M Ortega; Andrew Cureton; Ryan Clark; Eric W Livingston; Ted A Bateman; Moshe Levi; Karen B King; Virginia L Ferguson
Journal:  Bone       Date:  2016-02-06       Impact factor: 4.398

4.  Assessment of lamellar level properties in mouse bone utilizing a novel spherical nanoindentation data analysis method.

Authors:  Siddhartha Pathak; Shraddha J Vachhani; Karl J Jepsen; Haviva M Goldman; Surya R Kalidindi
Journal:  J Mech Behav Biomed Mater       Date:  2012-05-11

Review 5.  Application of Elastography for the Noninvasive Assessment of Biomechanics in Engineered Biomaterials and Tissues.

Authors:  Woong Kim; Virginia L Ferguson; Mark Borden; Corey P Neu
Journal:  Ann Biomed Eng       Date:  2016-01-20       Impact factor: 3.934

6.  The inferomedial femoral neck is compromised by age but not disease: Fracture toughness and the multifactorial mechanisms comprising reference point microindentation.

Authors:  T Jenkins; O L Katsamenis; O G Andriotis; L V Coutts; B Carter; D G Dunlop; R O C Oreffo; C Cooper; N C Harvey; P J Thurner
Journal:  J Mech Behav Biomed Mater       Date:  2017-06-30

Review 7.  Exploring the Mechanical Properties and Performance of Type-I Collagen at Various Length Scales: A Progress Report.

Authors:  Shirsha Bose; Simin Li; Elisa Mele; Vadim V Silberschmidt
Journal:  Materials (Basel)       Date:  2022-04-08       Impact factor: 3.748

  7 in total