Literature DB >> 21092832

Nonlinear contrast imaging with an array-based micro-ultrasound system.

A Needles1, M Arditi, N G Rognin, J Mehi, T Coulthard, C Bilan-Tracey, E Gaud, P Frinking, D Hirson, F S Foster.   

Abstract

The main goal of this study was to determine the optimal strategy for a real-time nonlinear contrast mode for small-animal imaging at high frequencies, on a new array-based micro-ultrasound system. Previously reported contrast imaging at frequencies above 15 MHz has primarily relied on subtraction schemes involving B-mode image data. These approaches provide insufficient contrast to tissue ratios under many imaging conditions. In this work, pulse inversion, amplitude modulation and combinations of these were systematically investigated for the detection of nonlinear fundamental and subharmonic signal components to maximize contrast-to-tissue ratio (CTR) in the 18-24 MHz range. From in vitro and in vivo measurements, nonlinear fundamental detection with amplitude modulation provided optimal results, allowing an improvement in CTR of 13 dB compared with fundamental imaging. Based on this detection scheme, in vivo parametric images of murine kidneys were generated using sequences of nonlinear contrast images after intravenous bolus injections of microbubble suspensions. Initial parametric images of peak enhancement (PE), wash-in rate (WiR) and rise time (RT) are presented. The parametric images are indicative of blood perfusion kinetics, which, in the context of preclinical imaging with small animals, are anticipated to provide valuable insights into the progression of human disease models, where blood perfusion plays a critical role in either the diagnosis or treatment of the disease.
Copyright © 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21092832     DOI: 10.1016/j.ultrasmedbio.2010.08.012

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  36 in total

1.  Assessment of Inflammation in an Acute on Chronic Model of Inflammatory Bowel Disease with Ultrasound Molecular Imaging.

Authors:  Steven Machtaler; Ferdinand Knieling; Richard Luong; Lu Tian; Jürgen K Willmann
Journal:  Theranostics       Date:  2015-08-08       Impact factor: 11.556

2.  High and low frequency subharmonic imaging of angiogenesis in a murine breast cancer model.

Authors:  Manasi Dahibawkar; Mark A Forsberg; Aditi Gupta; Samantha Jaffe; Kelly Dulin; John R Eisenbrey; Valgerdur G Halldorsdottir; Anya I Forsberg; Jaydev K Dave; Andrew Marshall; Priscilla Machado; Traci B Fox; Ji-Bin Liu; Flemming Forsberg
Journal:  Ultrasonics       Date:  2015-05-05       Impact factor: 2.890

3.  Micro-ultrasound for preclinical imaging.

Authors:  F Stuart Foster; John Hossack; S Lee Adamson
Journal:  Interface Focus       Date:  2011-06-08       Impact factor: 3.906

4.  Vascular contributions to 16p11.2 deletion autism syndrome modeled in mice.

Authors:  Julie Ouellette; Xavier Toussay; Cesar H Comin; Luciano da F Costa; Mirabelle Ho; María Lacalle-Aurioles; Moises Freitas-Andrade; Qing Yan Liu; Sonia Leclerc; Youlian Pan; Ziying Liu; Jean-François Thibodeau; Melissa Yin; Micael Carrier; Cameron J Morse; Peter Van Dyken; Christopher J Bergin; Sylvain Baillet; Christopher R Kennedy; Marie-Ève Tremblay; Yannick D Benoit; William L Stanford; Dylan Burger; Duncan J Stewart; Baptiste Lacoste
Journal:  Nat Neurosci       Date:  2020-07-13       Impact factor: 24.884

5.  Improved Contrast-Enhanced Ultrasound Imaging With Multiplane-Wave Imaging.

Authors:  Ping Gong; Pengfei Song; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-02       Impact factor: 2.725

6.  Phase change events of volatile liquid perfluorocarbon contrast agents produce unique acoustic signatures.

Authors:  Paul S Sheeran; Terry O Matsunaga; Paul A Dayton
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

7.  A novel method for quantitative myocardial contrast echocardiography in mice.

Authors:  E Alvarez; N D Dalton; Y Gu; D Smith; A Luong; M Hoshijima; K L Peterson; J Rychak
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-11-10       Impact factor: 4.733

8.  High-Frequency Multipulse, Plane-Wave Acoustic Contrast Imaging.

Authors:  Jeffrey A Ketterling; Ronald H Silverman
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-12-16       Impact factor: 2.725

9.  Ultrasound-guided delivery of microRNA loaded nanoparticles into cancer.

Authors:  Tzu-Yin Wang; Jung Woo Choe; Kanyi Pu; Rammohan Devulapally; Sunitha Bachawal; Steven Machtaler; Sayan Mullick Chowdhury; Richard Luong; Lu Tian; Butrus Khuri-Yakub; Jianghong Rao; Ramasamy Paulmurugan; Jürgen K Willmann
Journal:  J Control Release       Date:  2015-02-14       Impact factor: 9.776

10.  Hadamard-Encoded Multipulses for Contrast-Enhanced Ultrasound Imaging.

Authors:  Ping Gong; Pengfei Song; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-08-30       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.