Literature DB >> 21091010

Glaucoma drainage devices: a review of the past, present, and future.

Shuchi Patel1, Louis R Pasquale.   

Abstract

Glaucoma drainage devices are more frequently being used for glaucoma filtering surgeries, even those at low risk for failure with trabeculectomy. There are 4 major devices available: the Molteno, Baerveldt, Krupin, and Ahmed. The Molteno and Baerveldt are non-valved implants, while the Krupin and Ahmed are valved. The success rates of the different valves are about equal at approximately 70% with a mean intraocular pressure (IOP) lowering of at least 50% from the pre-operative IOP. Unfortunately, the failure rate is about 10% per year, leading to only 50% functional drainage devices at 5 years. Therefore, research on the biomaterials, shape, and technique of drainage implant surgery is being done in hopes of increasing long term success rates.

Entities:  

Mesh:

Year:  2010        PMID: 21091010     DOI: 10.3109/08820538.2010.518840

Source DB:  PubMed          Journal:  Semin Ophthalmol        ISSN: 0882-0538            Impact factor:   1.975


  30 in total

1.  [Anti-scarring effect of rapamycin in rabbits following glaucoma filtering surgery].

Authors:  Xin Kang; Ying Shen; Haixia Zhao; Zhaoge Wang; Wenying Guan; Ruichun Ge; Ruifang Wang; Xue Tai
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-11-30

2.  [New concepts for pressure-controlled glaucoma implants].

Authors:  R Allemann; O Stachs; K Falke; W Schmidt; S Siewert; K Sternberg; B Chichkov; A Wree; K-P Schmitz; R F Guthoff
Journal:  Ophthalmologe       Date:  2013-08       Impact factor: 1.059

Review 3.  Post-operative orbital imaging: a focus on implants and prosthetic devices.

Authors:  Ashok Adams; Kshitij Mankad; Cornelia Poitelea; David H Verity; Indran Davagnanam
Journal:  Neuroradiology       Date:  2014-08-07       Impact factor: 2.804

Review 4.  A novel suturing technique for filtering glaucoma surgery: the accordion suture.

Authors:  Mehmet Baykara; Basak Can Ermerak; Huri Sabur; Selim Genc
Journal:  Int J Ophthalmol       Date:  2017-12-18       Impact factor: 1.779

5.  Use of subconjunctival injections of 5-fluorouracil to rescue and prolong intraocular pressure reduction for a failing Ahmed glaucoma implant.

Authors:  Kevin Kaplowitz; Sarah Khodadadeh; Samantha Wang; Daniel Lee; James C Tsai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-04-08       Impact factor: 3.117

6.  Implantation of a second glaucoma drainage device.

Authors:  Brian A Francis; Rodrigo A B Fernandes; Handan Akil; Vikas Chopra; Bruno Diniz; James Tan; Alex Huang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-02-07       Impact factor: 3.117

7.  Outcomes of Ahmed valve surgery for refractory glaucoma in Dhahran, Saudi Arabia.

Authors:  Tariq Alasbali; Abdullah Ali Alghamdi; Rajiv Khandekar
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

8.  Short-term Postoperative Visual Acuity Decrease and Recovery after Ahmed Tube Shunt Procedure for Glaucoma.

Authors:  Yingna Liu; Lijuan Huang; Qian Zhao; Qian Liu; Robert L Stamper; Ying Han
Journal:  Ophthalmol Glaucoma       Date:  2020-04-22

9.  One-Year Feasibility Study of Replenish MicroPump for Intravitreal Drug Delivery: A Pilot Study.

Authors:  Juan-Carlos Gutiérrez-Hernández; Sean Caffey; Walid Abdallah; Phillip Calvillo; Roberto González; Jason Shih; Jeff Brennan; Jenna Zimmerman; Juan-Carlos Martínez-Camarillo; Anthony R Rodriguez; Rohit Varma; Arturo Santos; Gisela Sánchez; Mark Humayun
Journal:  Transl Vis Sci Technol       Date:  2014-07-01       Impact factor: 3.283

Review 10.  Fouling in ocular devices: implications for drug delivery, bioactive surface immobilization, and biomaterial design.

Authors:  Onyinye J Uwaezuoke; Pradeep Kumar; Viness Pillay; Yahya E Choonara
Journal:  Drug Deliv Transl Res       Date:  2021-01-16       Impact factor: 4.617

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.