Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition.

Guillaume Landry1, Brigitte Reniers, Lars Murrer, Ludy Lutgens, Esther Bloemen-Van Gurp, Jean-Philippe Pignol, Brian Keller, Luc Beaulieu, Frank Verhaegen.   

Abstract

PURPOSE: The objective of this work is to assess the sensitivity of Monte Carlo (MC) dose calculations to uncertainties in human tissue composition for a range of low photon energy brachytherapy sources: 125I, 103Pd, 131Cs, and an electronic brachytherapy source (EBS). The low energy photons emitted by these sources make the dosimetry sensitive to variations in tissue atomic number due to the dominance of the photoelectric effect. This work reports dose to a small mass of water in medium D(w,m) as opposed to dose to a small mass of medium in medium D(m,m).
METHODS: Mean adipose, mammary gland, and breast tissues (as uniform mixture of the aforementioned tissues) are investigated as well as compositions corresponding to one standard deviation from the mean. Prostate mean compositions from three different literature sources are also investigated. Three sets of MC simulations are performed with the GEANT4 code: (1) Dose calculations for idealized TG-43-like spherical geometries using point sources. Radial dose profiles obtained in different media are compared to assess the influence of compositional uncertainties. (2) Dose calculations for four clinical prostate LDR brachytherapy permanent seed implants using 125I seeds (Model 2301, Best Medical, Springfield, VA). The effect of varying the prostate composition in the planning target volume (PTV) is investigated by comparing PTV D90 values. (3) Dose calculations for four clinical breast LDR brachytherapy permanent seed implants using 103Pd seeds (Model 2335, Best Medical). The effects of varying the adipose/gland ratio in the PTV and of varying the elemental composition of adipose and gland within one standard deviation of the assumed mean composition are investigated by comparing PTV D90 values. For (2) and (3), the influence of using the mass density from CT scans instead of unit mass density is also assessed.
RESULTS: Results from simulation (1) show that variations in the mean compositions of tissues affect low energy brachytherapy dosimetry. Dose differences between mean and one standard deviation of the mean composition increasing with distance from the source are observed. It is established that the 125I and 131Cs sources are the least sensitive to variations in elemental compositions while 103Pd is most sensitive. The EBS falls in between and exhibits complex behavior due to significant spectral hardening. Results from simulation (2) show that two prostate compositions are dosimetrically equivalent to water while the third shows D90 differences of up to 4%. Results from simulation (3) show that breast is more sensitive than prostate with dose variations of up to 30% from water for 70% adipose/30% gland breast. The variability of the breast composition adds a +/- 10% dose variation.
CONCLUSIONS: Low energy brachytherapy dose distributions in tissue differ from water and are influenced by density, mean tissue composition, and patient-to-patient composition variations. The results support the use of a dose calculation algorithm accounting for heterogeneities such as MC. Since this work shows that variations in mean tissue compositions affect MC dosimetry and result in increased dose uncertainties, the authors conclude that imaging tools providing more accurate estimates of elemental compositions such as dual energy CT would be beneficial.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21089752     DOI: 10.1118/1.3477161

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: comparison of analytic and polyenergetic statistical reconstruction algorithms.

Authors:  Joshua D Evans; Bruce R Whiting; Joseph A O'Sullivan; David G Politte; Paul H Klahr; Yaduo Yu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

2.  Feasibility and clinical value of CT-guided 125I brachytherapy for metastatic soft tissue sarcoma after first-line chemotherapy failure.

Authors:  Zhiqiang Mo; Tao Zhang; Yanling Zhang; Zhanwang Xiang; Huzhen Yan; Zhihui Zhong; Fei Gao; Fujun Zhang
Journal:  Eur Radiol       Date:  2017-09-27       Impact factor: 5.315

3.  Tissue decomposition from dual energy CT data for MC based dose calculation in particle therapy.

Authors:  Nora Hünemohr; Harald Paganetti; Steffen Greilich; Oliver Jäkel; Joao Seco
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

Review 4.  Optimizing dual energy cone beam CT protocols for preclinical imaging and radiation research.

Authors:  Lotte E J R Schyns; Isabel P Almeida; Stefan J van Hoof; Benedicte Descamps; Christian Vanhove; Guillaume Landry; Patrick V Granton; Frank Verhaegen
Journal:  Br J Radiol       Date:  2016-11-02       Impact factor: 3.039

5.  Dosimetric effect of tissue heterogeneity for (125)I prostate implants.

Authors:  Susana Maria Oliveira; Nuno José Teixeira; Lisete Fernandes; Pedro Teles; Pedro Vaz
Journal:  Rep Pract Oncol Radiother       Date:  2014-04-16

6.  Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique.

Authors:  Andrew Sampson; Yi Le; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

7.  Experimental implementation of a polyenergetic statistical reconstruction algorithm for a commercial fan-beam CT scanner.

Authors:  Joshua D Evans; Bruce R Whiting; David G Politte; Joseph A O'Sullivan; Paul F Klahr; Jeffrey F Williamson
Journal:  Phys Med       Date:  2013-01-21       Impact factor: 2.685

8.  High throughput film dosimetry in homogeneous and heterogeneous media for a small animal irradiator.

Authors:  L Wack; W Ngwa; E Tryggestad; P Tsiamas; R Berbeco; S K Ng; J Hesser; P Zygmanski
Journal:  Phys Med       Date:  2013-03-17       Impact factor: 2.685

Review 9.  Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM.

Authors:  Christian Kirisits; Mark J Rivard; Dimos Baltas; Facundo Ballester; Marisol De Brabandere; Rob van der Laarse; Yury Niatsetski; Panagiotis Papagiannis; Taran Paulsen Hellebust; Jose Perez-Calatayud; Kari Tanderup; Jack L M Venselaar; Frank-André Siebert
Journal:  Radiother Oncol       Date:  2013-11-30       Impact factor: 6.280

10.  Quality Assurance Procedures based on Dosimetric, Gamma Analysis as a Fast Reliable Tool for Commissioning Brachytherapy Treatment Planning Systems.

Authors:  Grzegorz Zwierzchowski; Grzegorz Bieleda; Janusz Skowronek
Journal:  Radiol Oncol       Date:  2017-11-29       Impact factor: 2.991

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.