Literature DB >> 21087321

In vivo investigation on connective tissue healing to polished surfaces with different surface wettability.

Frank R Kloss1, Doris Steinmüller-Nethl1, Robert G Stigler1, Thomas Ennemoser1, Michael Rasse1, Oliver Hächl1.   

Abstract

OBJECTIVES: Connective tissue in contact to transgingival/-dermal implants presents itself as tight scar formation. Although rough surfaces support the attachment they increase bacterial colonisation as well. In contrast to surface roughness, little is known about the influence of surface wettability on soft-tissue healing in vivo. We therefore investigated the influence of different surface wettabilities on connective tissue healing at polished implant surfaces in vivo.
MATERIAL AND METHODS: Three polished experimental groups (titanium, titanium coated with hydrophobic nano-crystalline diamond (H-NCD) and titanium coated with hydrophilic nano-crystalline diamond (O-NCD) were inserted into the subcutaneous connective tissue of the abdominal wall of 24 rats. Animals were sacrificed after 1 and 4 weeks resulting in eight specimen per group per time point. Specimen were subjected to histological evaluation (van Giesson's staining) and immunohistochemistry staining for proliferating cell nuclear antigen (PCNA), fibronectin and tumour necrosis factor-alpha (TNF-α).
RESULTS: Histological evaluation revealed dense scar formation at the titanium and H-NCD surfaces. In contrast, the connective tissue was loose at the O-NCD surface with a significantly higher number of cells after 4 weeks. O-NCD demonstrated a strong expression of PCNA and fibronectin but a weak expression of TNF-α. In contrast, the PCNA and fibronectin expression was low at the titanium and H-NCD, with a strong signal of TNF-α at the H-NCD surface.
CONCLUSIONS: Hydrophilicity influences the connective tissue healing at polished implant surfaces in vivo positively. The attachment of connective tissue and the number of cells in contact to the surface were increased. Moreover, the inflammatory response is decreased at the hydrophilic surface.
© 2010 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21087321     DOI: 10.1111/j.1600-0501.2010.02038.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  11 in total

1.  Bio-inspired stable antimicrobial peptide coatings for dental applications.

Authors:  Kyle V Holmberg; Mahsa Abdolhosseini; Yuping Li; Xi Chen; Sven-Ulrik Gorr; Conrado Aparicio
Journal:  Acta Biomater       Date:  2013-06-19       Impact factor: 8.947

2.  Resistance to protein adsorption and adhesion of fibroblasts on nanocrystalline diamond films: the role of topography and boron doping.

Authors:  María Alcaide; Stavros Papaioannou; Andrew Taylor; Ladislav Fekete; Leonid Gurevich; Vladimir Zachar; Cristian Pablo Pennisi
Journal:  J Mater Sci Mater Med       Date:  2016-03-14       Impact factor: 3.896

3.  Boron-Doped Nanocrystalline Diamond Electrodes for Neural Interfaces: In vivo Biocompatibility Evaluation.

Authors:  María Alcaide; Andrew Taylor; Morten Fjorback; Vladimir Zachar; Cristian P Pennisi
Journal:  Front Neurosci       Date:  2016-03-08       Impact factor: 4.677

4.  Immunohistochemical Evaluation of Peri-Implant Soft Tissues around Machined and Direct Metal Laser Sintered (DMLS) Healing Abutments in Humans.

Authors:  Carlo Mangano; Francesco Guido Mangano; Jamil Awad Shibli; Leandro Amadeu Roth; Gianmaria d' Addazio; Adriano Piattelli; Giovanna Iezzi
Journal:  Int J Environ Res Public Health       Date:  2018-07-30       Impact factor: 3.390

5.  Immunohistochemical Results of Soft tissues Around a New Implant Healing-Abutment Surface: A Human Study.

Authors:  Barbara Ghinassi; Gianmaria D'Addazio; Angela Di Baldassarre; Beatrice Femminella; Giorgio Di Vincenzo; Maurizio Piattelli; Giulia Gaggi; Bruna Sinjari
Journal:  J Clin Med       Date:  2020-04-02       Impact factor: 4.241

6.  Laser microgrooved vs. machined healing abutment disconnection/reconnection: a comparative clinical, radiographical and biochemical study with split-mouth design.

Authors:  Renzo Guarnieri; Gabriele Miccoli; Rodolfo Reda; Alessandro Mazzoni; Dario Di Nardo; Luca Testarelli
Journal:  Int J Implant Dent       Date:  2021-03-17

7.  Improved response of human gingival fibroblasts to titanium coated with micro-/nano-structured tantalum.

Authors:  Chu-Nan Zhang; Lin-Yi Zhou; Shu-Jiao Qian; Ying-Xin Gu; Jun-Yu Shi; Hong-Chang Lai
Journal:  Int J Implant Dent       Date:  2021-05-03

8.  Impact of Nano-Crystalline Diamond Enhanced Hydrophilicity on Cell Proliferation on Machined and SLA Titanium Surfaces: An In-Vivo Study in Rodents.

Authors:  Robert Gerhard Stigler; Kathrin Becker; Michela Bruschi; Doris Steinmüller-Nethl; Robert Gassner
Journal:  Nanomaterials (Basel)       Date:  2018-07-13       Impact factor: 5.076

9.  Gingival Response to Dental Implant: Comparison Study on the Effects of New Nanopored Laser-Treated vs. Traditional Healing Abutments.

Authors:  Barbara Ghinassi; Angela Di Baldassarre; Gianmaria D'Addazio; Tonino Traini; Mauro Andrisani; Giorgio Di Vincenzo; Giulia Gaggi; Maurizio Piattelli; Sergio Caputi; Bruna Sinjari
Journal:  Int J Mol Sci       Date:  2020-08-22       Impact factor: 5.923

10.  Poly-L-Lysine and Human Plasmatic Fibronectin Films as Proactive Coatings to Improve Implant Biointegration.

Authors:  Anamar Miranda; Damien Seyer; Carla Palomino-Durand; Houda Morakchi-Goudjil; Mathilde Massonie; Rémy Agniel; Hassan Rammal; Emmanuel Pauthe; Adeline Gand
Journal:  Front Bioeng Biotechnol       Date:  2022-01-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.