Literature DB >> 21085028

Biomechanical analysis of fixation of middle third fractures of the clavicle.

Darren S Drosdowech1, Stuart E E Manwell, Louis M Ferreira, Danny P Goel, Kenneth J Faber, James A Johnson.   

Abstract

OBJECTIVE: This biomechanical study compares four different techniques of fixation of middle third clavicular fractures.
METHODS: Twenty fresh-frozen clavicles were randomized into four groups. Each group used a different fixation device (3.5 Synthes reconstruction plate, 3.5 Synthes limited contact dynamic compression plate, 3.5 Synthes locking compression plate, and 4.5 DePuy Rockwood clavicular pin). All constructs were mechanically tested in bending and torque modes both with and without a simulated inferior cortical defect. Bending load to failure was also conducted. The four groups were compared using an analysis of variance test.
RESULTS: The plate constructs were stiffer than the pin during both pure bending and torque loads with or without an inferior cortical defect. Bending load to failure with an inferior cortical defect revealed that the reconstruction plate was weaker compared with the other three groups. The limited contact and locking plates were stiffer than the reconstruction plate but demonstrated statistical significance only with the cortical defect.
CONCLUSIONS: As hypothesized, the 3.5 limited contact dynamic compression plate and 3.5 locking compression plate demonstrated the greatest resistance to bending and torque loads, especially in the presence of simulated comminution of a middle third clavicular fracture. The reconstruction plate demonstrated lower stiffness and strength values compared with the other plates, especially with a cortical defect, whereas the pin showed poor resistance to bending and torque loads in all modes of testing. This information may help surgeons to choose the most appropriate method of fixation when treating fractures of the middle third of the clavicle.

Entities:  

Mesh:

Year:  2011        PMID: 21085028     DOI: 10.1097/BOT.0b013e3181d8893a

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  14 in total

Review 1.  External fixators in the treatment of midshaft clavicle non-unions: a systematic review.

Authors:  Tim Barlow; Piyush Upadhyay; David Barlow
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-20

2.  S-shaped titanium endomedullary nail reduces telescoping of comminuted midshaft clavicular fractures.

Authors:  Ronny Langenhan; Stefanie Bushuven; Niklas Reimers; Axel Probst
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-09-09

3.  High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures.

Authors:  Martijn H J Hulsmans; Mark van Heijl; R Marijn Houwert; Eric R Hammacher; Sven A G Meylaerts; Michiel H J Verhofstad; Marcel G W Dijkgraaf; Egbert J M M Verleisdonk
Journal:  Clin Orthop Relat Res       Date:  2016-11-09       Impact factor: 4.176

4.  Stability of mid-shaft clavicle fractures after plate fixation versus intramedullary repair and after hardware removal.

Authors:  Sean D Smith; Coen A Wijdicks; Kyle S Jansson; Robert E Boykin; Frank Martetschlaeger; Peter-Paul de Meijer; Peter J Millett; Tom R Hackett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-01-31       Impact factor: 4.342

5.  Is removal of clavicle plate after fracture union necessary?

Authors:  Janey Wang; Ramiah Chidambaram; Daniel Mok
Journal:  Int J Shoulder Surg       Date:  2011-10

6.  Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study.

Authors:  Langqing Zeng; Haifeng Wei; Yanjie Liu; Wen Zhang; Yao Pan; Wei Zhang; Changqing Zhang; Bingfang Zeng; Yunfeng Chen
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

Review 7.  Intramedullary Nailing Versus Plate Fixation for the Treatment Displaced Midshaft Clavicular Fractures: A Systematic Review and Meta-Analysis.

Authors:  Nasir Hussain; Corey Sermer; Parker J Prusick; Laura Banfield; Amit Atrey; Mohit Bhandari
Journal:  Sci Rep       Date:  2016-10-20       Impact factor: 4.379

Review 8.  Operative versus nonoperative treatment for displaced midshaft clavicle fractures: a meta-analysis based on current evidence.

Authors:  Xin-Hua Wang; Wei-Jun Guo; A-Bing Li; Guang-Jun Cheng; Tao Lei; You-Ming Zhao
Journal:  Clinics (Sao Paulo)       Date:  2015-08       Impact factor: 2.365

9.  Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study.

Authors:  Alex K Gilde; Clifford B Jones; Debra L Sietsema; Martin F Hoffmann
Journal:  J Orthop Surg Res       Date:  2014-07-04       Impact factor: 2.359

10.  Comparison of conventional reconstruction plate versus direct metal laser sintering plate: an in vitro mechanical characteristics study.

Authors:  Pusheng Xie; Hanbin Ouyang; Yuping Deng; Yang Yang; Jing Xu; Wenhua Huang
Journal:  J Orthop Surg Res       Date:  2017-09-02       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.