Literature DB >> 21085007

Reduced polyp detection as endoscopy shift progresses: experience with screening colonoscopy at a tertiary-care hospital.

Millie D Long1, Christopher Martin, Robert S Sandler, Hans H Herfarth, Nicholas J Shaheen, Evan S Dellon.   

Abstract

GOALS: To determine whether polyp detection rates are reduced as time progresses through half and full-day endoscopy shifts.
BACKGROUND: Polyp detection on colonoscopy may be reduced during colonoscopies performed later in the day. STUDY: Retrospective analysis of screening colonoscopies performed by attending physicians only between August 2003 and August 2005 at University of North Carolina Hospitals. The primary outcome was detection of any polyp. The secondary outcome was adenoma detection. Both were assessed by time of day and shift type.
RESULTS: A total of 3421 eligible screening colonoscopies, performed by 20 attending gastroenterologists, were analyzed. Polyp detection rate for colonoscopies initiated before 9 AM was 48.6%, versus 34.0% for those initiated after 4:00 PM (P=0.04). On multivariate analysis, each hour of the day was associated with reduced odds of polyp detection [adjusted odds ratio (OR) 0.93, 95% confidence interval (CI) 0.89-0.98 for any polyp; adjusted OR: 0.94, 95% CI: 0.89-0.98 for adenoma]. When evaluated by physician shift, the odds of polyp detection were reduced in the last 1.5 hours compared with the first 1.5 hours of the shift, regardless of the length or timing of the shift (AM shift: OR: 0.63, 95% CI: 0.41-0.96; PM shift: OR: 0.79, 95% CI: 0.42-1.46; and full-day shift: OR: 0.67, 95% CI: 0.44-1.00).
CONCLUSIONS: Polyp detection by attending tertiary-care gastrointestinal physicians is reduced as time progresses during both half and full-day endoscopy shifts. These findings have implications for future quality improvement interventions.

Entities:  

Mesh:

Year:  2011        PMID: 21085007     DOI: 10.1097/MCG.0b013e3181fd2998

Source DB:  PubMed          Journal:  J Clin Gastroenterol        ISSN: 0192-0790            Impact factor:   3.062


  11 in total

1.  Improved bowel preparation increases polyp detection and unmasks significant polyp miss rate.

Authors:  Ioannis S Papanikolaou; Athanasios D Sioulas; Nektarios Magdalinos; Iosif Beintaris; Lazaros-Dimitrios Lazaridis; Dimitrios Polymeros; Chrysoula Malli; George D Dimitriadis; Konstantinos Triantafyllou
Journal:  World J Clin Cases       Date:  2015-10-16       Impact factor: 1.337

2.  Different screening definitions have little impact on polypectomy rate estimates.

Authors:  Mengzhu Jiang; Maida J Sewitch; Lawrence Joseph; Alan N Barkun
Journal:  Can J Gastroenterol       Date:  2012-11       Impact factor: 3.522

3.  Adenoma Detection Rate Falls at the End of the Day in a Large Multi-site Sample.

Authors:  Felippe O Marcondes; Rebecca A Gourevitch; Robert E Schoen; Seth D Crockett; Michele Morris; Ateev Mehrotra
Journal:  Dig Dis Sci       Date:  2018-02-03       Impact factor: 3.199

4.  Timing of procedure and compliance with outpatient endoscopy among an underserved population in an inner-city tertiary institution.

Authors:  Dilhana S Badurdeen; Nisser A Umar; Rehana Begum; Andrew K Sanderson; Momodu Jack; Getachew Mekasha; John Kwagyan; Duane T Smoot; Adeyinka O Laiyemo
Journal:  Ann Epidemiol       Date:  2012-05-08       Impact factor: 3.797

5.  Optimized sedation improves colonoscopy quality long-term.

Authors:  Konstantinos Triantafyllou; Athanasios D Sioulas; Theodora Kalli; Nikolaos Misailidis; Dimitrios Polymeros; Ioannis S Papanikolaou; George Karamanolis; Spiros D Ladas
Journal:  Gastroenterol Res Pract       Date:  2015-01-08       Impact factor: 2.260

6.  Colonoscopic polyp detection rate is stable throughout the workday including evening colonoscopy sessions.

Authors:  David Thurtle; Michael Pullinger; Jordan Tsigarides; Iris McIntosh; Carla Steytler; Ian Beales
Journal:  F1000Res       Date:  2014-05-13

7.  Does a Pre-Training Program Influence Colonoscopy Proficiency during Fellowship?

Authors:  Duk Hwan Kim; Soo Jung Park; Jae Hee Cheon; Tae Il Kim; Won Ho Kim; Sung Pil Hong
Journal:  PLoS One       Date:  2016-10-20       Impact factor: 3.240

8.  Differences between morning and afternoon colonoscopies for adenoma detection in female and male patients.

Authors:  Shailendra Singh; Manish Dhawan; Monica Chowdhry; Michael Babich; Elie Aoun
Journal:  Ann Gastroenterol       Date:  2016-09-06

9.  Factors predicting the colorectal adenoma detection rate in colonoscopic screening of a Chinese population: A prospective study.

Authors:  Han Wang; Pu Wang; Xiaogang Liu; Liangping Li; Xun Xiao; Peixi Liu; Di Zhang; Yi Li; Guangre Xu; Mengtian Tu; Yan Song
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

10.  Screening colonoscopy: should we focus more on technique and less on technology?

Authors:  Noor Mohammed; Venkataraman Subramanian
Journal:  F1000Prime Rep       Date:  2013-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.