Literature DB >> 21081829

A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements.

Mårten Dalaryd1, Gabriele Kragl, Crister Ceberg, Dietmar Georg, Brendan McClean, Sacha af Wetterstedt, Elinore Wieslander, Tommy Knöös.   

Abstract

A Monte Carlo model of an Elekta Precise linear accelerator has been built and verified by measured data for a 6 and 10 MV photon beam running with and without a flattening filter in the beam line. In this study the flattening filter was replaced with a 6 mm thick copper plate, provided by the linac vendor, in order to stabilize the beam. Several studies have shown that removal of the filter improves some properties of the photon beam, which could be beneficial for radiotherapy treatments. The investigated characteristics of this new beam included output, spectra, mean energy, half value layer and the origin of scattered photons. The results showed an increased dose output per initial electron at the central axis of 1.76 and 2.66 for the 6 and 10 MV beams, respectively. The number of scattered photons from the accelerator head was reduced by (31.7 ± 0.03)% (1 SD) for the 6 MV beam and (47.6 ± 0.02)% for the 10 MV beam. The photon energy spectrum of the unflattened beam was softer compared to a conventional beam and did not vary significantly with the off-axis distance, even for the largest field size (0-20 cm off-axis).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21081829     DOI: 10.1088/0031-9155/55/23/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  A surface energy spectral study on the bone heterogeneity and beam obliquity using the flattened and unflattened photon beams.

Authors:  James C L Chow; Amir M Owrangi
Journal:  Rep Pract Oncol Radiother       Date:  2015-11-30

2.  Dosimetric study of the plan quality and dose to organs at risk on tangential breast treatments using the Halcyon linac.

Authors:  Everardo Flores-Martinez; Gwe-Ya Kim; Catheryn M Yashar; Laura I Cerviño
Journal:  J Appl Clin Med Phys       Date:  2019-06-11       Impact factor: 2.102

3.  Unflattened photon beams from the standard flattening filter free accelerators for radiotherapy: Advantages, limitations and challenges.

Authors:  Sunil Dutt Sharma
Journal:  J Med Phys       Date:  2011-07

4.  Acceptance criteria for flattening filter-free photon beam from standard medical electron linear accelerator: AERB task group recommendations.

Authors:  G Sahani; S D Sharma; P K Dash Sharma; D D Deshpande; P S Negi; V K Sathianarayanan; G K Rath
Journal:  J Med Phys       Date:  2014-10

5.  Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

Authors:  Daniel G Zhang; Vladimir Feygelman; Eduardo G Moros; Kujtim Latifi; Geoffrey G Zhang
Journal:  PLoS One       Date:  2014-10-02       Impact factor: 3.240

6.  Dosimetric properties of a beam quality-matched 6 MV unflattened photon beam.

Authors:  Yunfei Huang; R Alfredo Siochi; John E Bayouth
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

7.  Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes.

Authors:  Daniel L Saenz; Ganesh Narayanasamy; Wilbert Cruz; Nikos Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

8.  Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator.

Authors:  Mukesh N Meshram; Srimanta Pramanik; C P Ranjith; Saravana K Gopal; Rishabh Dobhal
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

9.  Surface dose measurements and comparison of unflattened and flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj; Girigesh Yadav; Ananda Giribabu; Karthikeyan Srinivasan; Venkadamanickam Gurusamy; Kothanda Raman; Kaviarasu Karunakaran; Rajesh Thiyagarajan
Journal:  J Med Phys       Date:  2016 Apr-Jun

10.  Feasibility of using nonflat photon beams for whole-breast irradiation with breath hold.

Authors:  Yuenan Wang; Andrew Vassil; Rahul Tendulkar; John Bayouth; Ping Xia
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

View more