Literature DB >> 21076727

Implantable cardioverter defibrillator: charge saver, not syncope saver!

Diego Chemello1, Anandaraja Subramanian, Sheila Watkins, Krishnakumar Nair, Kumaraswamy Nanthakumar.   

Abstract

In patients with an implantable cardioverter defibrillator, empirical antitachycardia pacing/burst pacing (ATP) is associated with a significantly decreased rate of appropriate shocks. The use of ATP as first-line therapy in ventricular tachycardia promotes less pain and better quality of life because the number of shocks is reduced. Additionally, battery longevity is substantially increased with this strategy. Based on this, device manufacturers have developed new algorithms to optimize the use of ATP and shocks in patients with an implantable cardioverter defibrillator. The present report describes a case in which the use of one of these new algorithms was associated with a significant delay in tachycardia termination and, consequently, led to syncope.

Entities:  

Mesh:

Year:  2010        PMID: 21076727      PMCID: PMC2989360          DOI: 10.1016/s0828-282x(10)70458-x

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  5 in total

1.  Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports.

Authors:  William H Maisel; Megan Moynahan; Bram D Zuckerman; Thomas P Gross; Oscar H Tovar; Donna-Bea Tillman; Daniel B Schultz
Journal:  JAMA       Date:  2006-04-26       Impact factor: 56.272

2.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

3.  Canadian implantable defibrillator study (CIDS) : a randomized trial of the implantable cardioverter defibrillator against amiodarone.

Authors:  S J Connolly; M Gent; R S Roberts; P Dorian; D Roy; R S Sheldon; L B Mitchell; M S Green; G J Klein; B O'Brien
Journal:  Circulation       Date:  2000-03-21       Impact factor: 29.690

4.  Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results.

Authors:  Mark S Wathen; Paul J DeGroot; Michael O Sweeney; Alice J Stark; Mary F Otterness; Wayne O Adkisson; Robert C Canby; Koroush Khalighi; Christian Machado; Donald S Rubenstein; Kent J Volosin
Journal:  Circulation       Date:  2004-10-18       Impact factor: 29.690

5.  Implantable cardioverter defibrillator recipients: quality of life in recipients with and without ICD shock delivery: a prospective study.

Authors:  H C M Kamphuis; J R J de Leeuw; R Derksen; R N W Hauer; J A M Winnubst
Journal:  Europace       Date:  2003-10       Impact factor: 5.214

  5 in total